45
(16)
I/O function assignment setting command
Offset
Label
Setting value (Hex)
0
INC
Please enter an arbitrary value different from the value previously
sent.
1
CMD
0x13
2
RSV1
0x00
3
RSV2
0x00
4
DATA1
※
ASCII code
Target I / O module number
Setting value (Hex)
‘
0
’:
IO1
0x30
‘1’:
IO2
0x31
5
DATA2
※
ASCII code
Input / output type Setting value (Hex)
‘I’:
Input
0x49
‘O’:
Output
0x4F
6
DATA3
※
ASCII code
Terminal number
Setting value (Hex)
‘0’
0x30
‘1’
0x31
‘2’
0x32
‘3’
0x33
‘4’
0x34
‘5’
0x35
‘6’
0x36
‘7’
0x37
7
DATA4
※
ASCII code
Input function type
Setting value (Hex)
‘0’:
Addr0
0x30
‘1’:
Addr1
0x31
‘2’:
Addr2
0x32
‘3’:
Addr3
0x33
‘4’:
Dreq
0x34
‘5’:
Comp0
0x35
‘6’:
Comp1
0x36
‘7’:
Comp2
0x37
‘8’:
Reset
0x38
‘9’:
Preset
0x39
‘A’:
Reset_org
0x41
‘B’:
Mode0
0x42
‘C’:
Mode1
0x43
‘D’:
Start
0x44
‘E’:
Pause
0x45
‘X’:
No_Func
0x58