43
(14)
Comparator threshold setting command
Offset
Label
Setting value (Hex)
0
INC
Please enter an arbitrary value different from the value previously
sent.
1
CMD
0x11
2
RSV1
0x00
3
RSV2
0x00
4
DATA1
※
ASCII code
Frame number
Setting value (Hex)
‘
A
’~’
J
’
0x30
~
0x39
‘
K
’~’
P
’
0x41
~
0x46
5
DATA2
※
ASCII code
Comparator group number Setting value (Hex)
‘1’
0x31
‘2’
0x32
‘3’
0x33
‘4’
0x34
‘5’
0x35
‘6’
0x36
‘7’
0x37
‘8’
0x38
6
DATA3
※
ASCII code
Comparator step number
Setting value (Hex)
‘1’
0x31
‘2’
0x32
‘3’
0x33
‘4’
0x34
7
~
10
DATA4
~
DATA7
Comparator threshold
※
Integer type 8 digits (Last 4 digits after decimal point) 4 bytes Hex
value
(Example)
+
0.1
μ
m
→
+1000 (0x3E8)
-
0.1
μ
m
→
-1000 (0xFC18)
11
~
15
DATA8
~
DATA11
Dummy
0x00