EN
18
www.magmaweld.com
USER MANUAL | MANUEL D’UTILISATION | РУКОВОДСТВО ПО ЭКСПЛУАТАЦИИ | KULLANIM KILAVUZU
monoTIG 220ip / 220ipw / 220ip AC-DC / 220ipw AC-DC
• Secure the argon gas cylinder
(a)
with a chain.
• Use safe high quality regulators
(b)
and heaters approved by the standards to work safely and achieve the best
results.
• Keep the gas cylinder valve
(c)
open for a while, so that possible sediment and particles are discharged.
• Connect the gas regulator to the gas cylinder, making sure that the thread on the gas outlet of the gas cylinder
and the nut of the regulator overlap.
• Connect one end of the cylinder hose
(d)
to the gas regulator and the other end to the gas inlet at the rear of the
machine and turn on the gas cylinder valve.
• Adjust the flow rate with the flow regulating valve
(e)
.
• Make sure the connections are free of leakages.
2.5.2 Gas Connections
Electrode
Diameter
(mm)
Nozzle
Diameter
(mm)
Welding
Current
(ADC)
Gas Flow
(lt/sec)
1.0
1.6
6.3
9.5
30-70
30-150
6-8
6-8
• TIG Torch Connection; the trigger should be connected to the control socket with the terminals
1-2-3-4-5
as
shown.
(1)
Soldering direction has been taken as the reference.
(2)
Soldering direction has been taken as the reference.
2.5.3 Trigger and Pedal System Socket Connections
c
a
b
e
d
• Adjustable Pedal Connection; It should be secured to the pedal socket with the ends
3-4-5-6
.
Installation