EN
19
www.magmaweld.com
USER MANUAL | MANUEL D’UTILISATION | РУКОВОДСТВО ПО ЭКСПЛУАТАЦИИ | KULLANIM KILAVUZU
monoTIG 220ip / 220ipw / 220ip AC-DC / 220ipw AC-DC
(3)
Soldering direction has been taken as the reference.
2.5.4 Grounding Clamps Connections
2.5.5 Installation of Torch Consumables
• Insert the grounding clamps cable plug
(a)
into the positive terminal socket and tighten it by turning right.
• To improve the welding quality, firmly connect the grounding pliers
(b)
to the workpiece as close as possible to
the welding area.
• The ceramic gas nozzle
(5)
and the tungsten electrode
(1)
must be selected according to the operating
current and the shape of the workpiece. Accordingly,
the diameters of the collet
(3)
and the collet body
(4)
must match with the diameter of the tungsten
electrode.
• Remove the back cap
(2)
.
• Remove the existing electrode from the collet and
match the diameter of the new tungsten electrode.
• Secure the collet to the torch.
• Secure the back cap firmly head firmly.
Figure 3 : Installation of Torch Consumables
1
3
4
5
a
b
Installation