1-800-MAGLINE
(624-5463)
Lift
Plus
®
22
ELECTRICAL SYSTEM
BATTERY
TOOLS NEEDED: #2 OR #3 PHILLIPS SCREWDRIVER
Removal:
1. Turn off the LiftPlus; fold and lock into place.
2. Remove the battery cover.
3. Slide the connectors off the positive and negative terminals.
4. Remove the battery bracket using a Phillips driver.
5. Inspect the Battery for cracks, leaks, and corrosion.
If you find cracks, leakage or corrosion on the battery:
a. Contact Customer Service to order a replacement battery - do not operate the LiftPlus until repairs are
made.
b. Wear acid-resistant gloves and chemical goggles. Do not let leakage contact your skin.
c.
If leakage gets onto the skin, flush immediately with water and mild soap. If irritation develops, seek
medical attention. If the leakage gets into the eyes, flush with clean water for 15 minutes and seek
immediate medical attention.
4. Remove the battery.
Installation:
1. Place battery in battery box.
2. Connect the red wire to the positive terminal and the black wire to the negative terminal.
3. Install the battery bracket using two 10-32 x .500” long screws with lock washers.
4. Be sure to connect the grounding wire ring terminal around on of the battery bracket screws.
5. Install the battery cover; unfold and lock the LiftPlus.
Item
Qty.
Part Number
A Battery bracket
1
530520
B Truss head Phillips machine screw - #10-32 x
.500” long
2
80348
C Circuit breaker w/wiring harness - 15A,
32 VDC, 250 VAC
1
534415
D Battery - 12V-15.0 Ah
1
61017
E Battery box
1
533500
E
A
B
C
D