21
1
Not Used
A10
0
Ignition command from the Extinguishing: 0=the
system goes into Recovery Ignition;
0
n°
1
Ignition command from the Extinguishing: 1=it goes
into Check Up
A13
0
System Management for Boiler Thermostat satisfied:
the system goes into Modulation;
1
n°
1
System Management for Boiler Thermostat satisfied:
before the system goes in Modulation and after, if
boiler temperature>(Boiler TheD23), goes
in Standby;
2
System Management for Boiler Thermostat satisfied:
in Winter the system goes in Modulation, in Summer
the system goes in Modulation and if the boiler
temperature>(BoilerTheD23) in Standby
A14
0
Management without Pressure Sensor: 0 = disabled;
0
n°
1
Management without Pressure Sensor: 1 = enabled
A26
0
Management to exit from Standby: 0=immediate,
1
n°
1
Management to exit from Standby: 1=only upon the
expiry of the timer T13 and if the exhaust flue gas
temperature<Th28.
A27
0
System management in Standby: 0=brazier
Extinguishing;
0
n°
1
System management in Standby: 1=Brazier
Maintenance
A28
0
Management Auger Brake: 0= not enabled;
0
n°
1
Management Auger Brake: 1=enabled
A29
0
System Management in Standby for Room
Thermostat: 0= it does not exit for DHW demand
1
n°
1
System Management in Standby for Room
Thermostat: 1=g it exits for DHW demand
A32
0
Internal Chrono Management:Ignition/Extinguishing
0
n°
1
Internal Chrono Management:RunMode/Modulation
2
Internal Chrono Management:RunMode/StandBy
3
Internal Chrono block the Pump1 until Th21
4
Internal Chrono Management:RunMode/StandBy
and block the Pump1 until Th21
A41
0
Pump operation also in OFF
0
n°
1
Pump dissimilated in OFF
A53
0
Management lack of net supply voltage: 0=system in
Block with Er15 if there was no supply voltage for
more than T89 minutes;
0
n°
1
Management lack of net supply voltage: system in
Recovery Ignition if there was no voltage supply for
more than T89 minutes
A61
0
Periodical Cleaning Management enabled only if in
Run Mode.
0
n°
1
Periodical Cleaning Management enabled also in
Modulation.
P02
Maximum number of attempted Ignition
2
n°
P03
Number of Working Combustion Powers
5
n°
P04
Number of recipes shown to the user
1
n°
P12
Refill feature with error in case of threshold lower than
the 10%: 0=error disabled, 1=error enabled
1
P20
Pressure Sensor Selection
0
n°
P26
Hydraulic Plant Configuration (see pag. 9)
0
n°