Page 11
2.1.6. Manual Operation (Total Control)
In emergency the appliance can be operated
manually as follows:
1. Turn the Gas Rate Adjusting knob fully
clockwise to the
OFF
position. A clicking
sound will be audible, but this is perfectly
alright.
2. Turn the Manual knob clockwise to
MAN
position (see
Figure 16
).
3. Ensure that the ON/OFF switch is in the
ON
(
–
) position.
4. Using a rigid slender object (like a
screwdriver) depress the pilot valve
operator through the large hole in the
knob (see
Figure 17
) and light the pilot
using a match or lighted taper.
5. Keep the valve operator depressed for a
further 10 seconds and slowly release.
The pilot should stay alight. Repeat step
4 if necessary.
6. Turn the Manual knob anticlockwise to
the
ON
position.
7. Turn the Gas Rate adjusting knob
anticlockwise to the
ON
position to turn
the main burner on. Adjust this knob to
obtain the desired gas rate between
maximum and minimum.
8. To turn the main burner off, but leaving
the pilot on, turn the Gas Rate adjusting
knob fully clockwise past the
OFF
position.
9. To turn the pilot off place the
ON/OFF
switch to
OFF
(
O
) position.
M
A
N
NO
ON/OFF Switch
Manual
Knob
Gas Rate
Adjusting
Knob
O
N
O
FF
Figure 16
M
A
N
NO
Gas Rate
Adjusting
Knob
O
N
O
F
F
Figure 17
NOTE:
No attempt should be
made to relight the fire for at
least 3 minutes after the pilot
flame has been extinguished
either
intentionally
or
unintentionally.