Burley Magiglo fires are protected by  

UK patents 2193802, 2240620 and 2256920 

Other Patents Pending 

 

Magiglo is a registered trademark of Burley Appliances Ltd 

 

 

 

 

 

Burley Appliances Ltd, Lands End Way 

Oakham, Rutland, LE15 6RB 

 

Tel: 01572 725570     Fax: 01572 724390 

www.magiglo.co.uk     Email: [email protected] 

Summary of Contents for Custom 18 Plus

Page 1: ...S Fuel Effect Options Coal Effect Pebble Effect Control Options Manual Control Remote Control Total Control Detached Control For use on Natural Gas G20 at a supply pressure of 20mbar in GB and IE Ple...

Page 2: ...a defect in materials or workmanship occurring within one year of purchase Burley Magiglo will arrange to repair or replace the item free of charge Any claims under this warranty must be made through...

Page 3: ...1 5 deep 17 2 4 5 Pebble Effect Layout 18 2 5 Home Improvements 23 2 6 Cleaning Instructions 24 2 6 1 Cleaning the Fire Bed and the Imitation Coals Pebbles 24 2 6 2 Cleaning the Pilot 25 2 6 3 Black P...

Page 4: ...l Valve Replacement BM or Mertik GV34 42 4 3 4 Motor Replacement Remote Control Optimum Control Models 43 4 3 5 Replacing Mertik GV60 Valve Total Control 44 4 3 6 Replacing the Receiver Total Control...

Page 5: ...e to I S 813 2 The installation of the fire in GB should follow the recommendations of the following current British Standards BS 5871 Pt 3 Installation of Decorative Fuel Effect Gas Fires BS 6891 Pip...

Page 6: ...r use with Natural Gas G20 at 20mbar supply pressure 2 A separate means of isolating the gas supply must be provided near to the appliance to facilitate servicing An isolating valve has been supplied...

Page 7: ...m below Minimum opening free air in fire fret Minimum opening free air in ash pan cover Figure 1 Fire Front Specification Free Air Opening in Fire Fret Minimum 15 of total front area Ash Pan Cover Fre...

Page 8: ...Page 4 This page is left intentionally blank...

Page 9: ...re as shown and follow the appropriate operating instructions in the appropriate section Control Valve Operation Control Type Manual Manual BM Control See Section 2 1 1 on Page 6 Manual Manual Mertik...

Page 10: ...anually by applying a lighted match or taper to the pilot jet and following the above procedure NOTE No attempt should be made to relight the fire for at least 3 minutes after the pilot flame has been...

Page 11: ...GAS RATE ADJUSTING KNOB fully anticlockwise until you reach the stop position i e the maximum gas rate See Figure 9 4 The main burner will have cross lit from the pilot 5 Now the gas rate can be adju...

Page 12: ...his process the main burner will ignite from the pilot 7 By pressing the two buttons together to increase the gas rate and the lower button only to decrease the gas rate the valve can be manipulated t...

Page 13: ...to the main flame position 6 Press and hold the large flame button in Figure 12 until clicking is heard fully open 7 The main burner will have cross lit from the pilot 8 Now the gas rate can be adjus...

Page 14: ...s rate to desired setting press the large flame to increase the flame height or small flame to decrease the flame height on the handset see Figure 15 5 For fine adjustment tap the or buttons 6 To leav...

Page 15: ...10 seconds and slowly release The pilot should stay alight Repeat step 4 if necessary 6 Turn the Manual knob anticlockwise to the ON position 7 Turn the Gas Rate adjusting knob anticlockwise to the ON...

Page 16: ...eceiver Unit 1 Remove the receiver unit from under the fire burner or from wherever positioned if mounted remotely and remove the battery compartment cover see Figure 19 2 Replace the old batteries wi...

Page 17: ...wdriver 3 Remove the battery pack from the wall box and replace the spent batteries with new ones 4 off 1 5V AA batteries ensuring correct polarity 4 Insert the battery pack back into the wall box and...

Page 18: ...ng we recommend that you use a HEPA filtered vacuum to remove any dust and soot accumulated in and around the fire before and after working on the fire to ensure that the release of fibres from these...

Page 19: ...o round the perimeter as indicated on diagram 4 Unpack the random coals and proceed to bridge them across the aeration tubes starting with the middle row as shown on diagram as indicated in the figure...

Page 20: ...1 First Layer Random Coals Figure 22 Second Layer Random Coals Figure 23 Third Layer 2 4 3 Custom 18 Plus B and Custom 18 Plus S Example Coal Layouts up to 9 5 deep Medium Square Coals Aeration Tubes...

Page 21: ...tom 18 Plus S Example Coal Layouts up to 11 5 deep Medium Square Coals Aeration Tubes Medium Square Coals Small Square Coals Figure 27 First Layer Random Coals Figure 28 Second Layer Random Coals Figu...

Page 22: ...r Medium Pebbles Comprises of pebbles marked with letters C D and F Used on top of large pebbles for bridging across gaps Also used in a row in front of the fire Small Pebbles These are small pebbles...

Page 23: ...onstant moving of the pebbles causes the pebbles to disintegrate and or cause discolouration NOTE Pebbles must not be placed directly on the pilot assembly however pebbles may be placed suspended abov...

Page 24: ...THIRD LAYER TOP LAYER FRONT PEBBLES E or J EQUALLY SPACED H H H H AERATION TUBES LARGE PEBBLES K LARGE PEBBLES A B ON SIDES OF TRAY LARGE PEBBLES A B MEDIUM PEBBLES C D F PILOT MEDIUM PEBBLES C D F S...

Page 25: ...R TYPICAL PEBBLE LAYOUT FOR CUSTOM 18 PLUS B OR S UP TO 240MM DEEP FRONT PEBBLES E or J EQUALLY SPACED AERATION TUBES INSET PILOT H H H H LARGE PEBBLES A B LARGE PEBBLES K LARGE PEBBLES A B MEDIUM PEB...

Page 26: ...Page 22...

Page 27: ...ly appliances generating heat will create warm air convection currents that will transfer heat to any wall surface against which they are located Some soft furnishings including blown vinyl wallpapers...

Page 28: ...eramic Fibres RCF we recommend that the replaced items are not broken up but are sealed within heavy duty polythene bags and clearly labelled as RCF waste RCF waste may be disposed of in suitably lice...

Page 29: ...own unexpectedly 4 The pilot does not stay alight after releasing the control lever If any of the above symptoms show follow the instructions below for removing the offending blockage 1 Using a pair o...

Page 30: ...Page 26 This page is left intentionally blank...

Page 31: ...e room 3 The flue should be sound free from obstructions and if it has previously been used with a solid fuel or oil fired appliance it should be swept before installing this gas fire The flue must be...

Page 32: ...7 kW gross 10 0 kW gross Minimum setting pressure 2 0 mbar 2 0 mbar 3 5 mbar Gas G20 Natural Gas G20 Natural Gas G20 Natural Gas Injector 1 off 104 2 off 104 2 off 104 Gas inlet connection 8mm 8mm 10...

Page 33: ...Approved Document J paragraph 3 40 currently states Appliance should be placed on hearths unless a they are installed so that every part of any flame or incandescent material will be at least 225mm ab...

Page 34: ...y accommodate the depth of the fireplace furniture HW Must project a minimum of 150mm either side of any naked flame or incandescent material HD Must project a minimum of 300mm in front of any naked f...

Page 35: ...and two sides For a freestanding fire under a canopy or flue hood the hearth must extend completely under the fire and must be in accordance with the diagram below Figure 36 For a freestanding fire ag...

Page 36: ...unted decorative bar etc All Models W Must project a minimum of 150mm either side of any naked flame or incandescent material D Must project a minimum of 300mm in front of any naked flame or incandesc...

Page 37: ...may be met D W Figure 43 Example of physical barrier dimensions as stated in Table 2 D W Figure 44 Example of physical barrier dimensions as stated in Table 2 D W 50mm Min Figure 45 Example of physica...

Page 38: ...ded in accordance with the rules in force In other EC countries equivalent rules in force must be used 3 6 Contents Checklist Before proceeding with installation of the fire check the contents as foll...

Page 39: ...ject beyond the vertical plane of the fireplace opening 6 Connect the gas supply to the inlet of the gas valve via the isolating valve where supplied Route the cable for the Optimum Control if applica...

Page 40: ...e valve ensuring correct polarity The cable connectors must be matched to the appropriately sized spade connector Also ensure that the cable is neatly tucked away and not touching the underside of the...

Page 41: ...the heat shield and connect to the receiver as shown in Figure 49 keeping the cables clear of the underside of the tray Do not force the valve cable plug when inserting into the receiver it only fits...

Page 42: ...void too many sharp bends in the pipe 9 Form the supplied tubing to the shape of the route taken and cut off any excess length if necessary 10 Connect one end of the formed tubing to the injector elbo...

Page 43: ...vely the information is given on the data badge of the appliance 6 If the correct pressure cannot be achieved then some potential causes of low pressure are a Supply pipes are not of large enough diam...

Page 44: ...the instructions prior to commencing the spillage test Ceiling Fans If a ceiling cooling fan is fitted in the same room as the appliance the spillage test should be repeated Operated the fan in both c...

Page 45: ...that the gas and electrical supply where applicable have been isolated After any servicing or replacement of any parts the appliance should be re commissioned 4 2 Servicing Instructions As part of th...

Page 46: ...efit in reverse order ensuring that the lint guard is fitted 4 3 2 Injector Replacement 1 Undo the two compression nuts on the gas feed pipe to the injector elbow s and remove the pipe 2 Loosen the M5...

Page 47: ...he gas rate adjusting knob fully anticlockwise and gently manipulate the motor free from the valve see note See Figure 54 and Figure 55 7 Replace with new motor ensuring that the motor is hooked into...

Page 48: ...the receiver from under the heat shield and remove the batteries 2 Gently pull out the HT lead and the valve cable from the receiver see Figure 57 3 Unscrew and remove the SW and TC connections 4 Refi...

Page 49: ...ased a Loose thermocouple connection at control valve end Remake thermocouple ensuring the connection is firm b Faulty Thermocouple Replace complete pilot assembly Pilot and main burner go out when co...

Page 50: ...ll 4 AA batteries Remote Control will turn fire off but will not turn on Incorrect hand set operation Ensure two buttons are pressed to turn on A prolonged audible signal is heard when attempting to l...

Page 51: ...ycling WEEE Dispose of electrical equipment in an environmentally correct manner When disposing components containing Refractory Ceramic Fibres RCF we recommend that the items are not broken up but ar...

Page 52: ...ents 2193802 2240620 and 2256920 Other Patents Pending Magiglo is a registered trademark of Burley Appliances Ltd Burley Appliances Ltd Lands End Way Oakham Rutland LE15 6RB Tel 01572 725570 Fax 01572...