Page 2
Ventilation Requirements
1. When installing in GB, all models will require a minimum of 100cm
2
ventilation in the room
where the fire is installed and reference should be made to BS 5871 Part 3. In IE
reference should be made to the current edition of I.S.813 which makes clear the
conditions that must be met to demonstrate that sufficient ventilation is available.
2. If provided, any purpose provided ventilation must be checked periodically to ensure it is
free from obstructions.
3. When fitting the fire in Northern Ireland (NI), purpose provided ventilation must be
provided in accordance with the rules in force.
4. In other EC countries equivalent rules in force must be used.
Flue Requirements
1. The flue serving this appliance shall have no cross sectional dimension less than 175mm
(7”) e.g. 225mm (9”) by 225mm (9”) Masonry chimney or 175mm (7”) diameter clay liner.
2. The fireplace size shall be such that there is no spillage from the appliance.
Gas Supply
1. This range of decorative gas fires are suitable for use with Natural Gas (G20) at 20mbar
supply pressure.
2. A separate means of isolating the gas supply must be provided near to the appliance to
facilitate servicing. An isolating valve has been supplied with 18 Plus and 18 Plus/B
models for this purpose.
Declaration of Conformity
Burley Magiglo Ltd. declares that the appliance described in “Technical data” conforms to the
following standard(s) BS EN509:2000 + A1:2003 + A2:2004
Electrical Supply
Not applicable to this range of appliances.
1.1. Important Note About ODS Pilot
This fire is fitted with an ODS pilot which causes the appliance to shut down in the event of a
reduction of oxygen (e.g. caused by poor ventilation) in the room. Should this happen, follow
the lighting instructions to re-light the fire. In the event that the fire should shut down again,
do NOT attempt to re-light it but contact your gas installer for remedial action to be taken.
Under no circumstances should it be adjusted or put out of action by the installer
or the user. In case the pilot needs replacing, only the approved part (available
from your supplier or Burley Magiglo.) should be fitted. Note: if any part of the
pilot assembly becomes faulty the complete assembly will need replacing.