Page 3
1.1.
0B
Important Note About ODS Pilot
This fire is fitted with an ODS pilot which causes the appliance to shut down in the event of a
reduction of oxygen (e.g. caused by poor ventilation) in the room. Should this happen, follow
the lighting instructions to re-light the fire. In the event that the fire should shut down again,
do NOT attempt to re-light it but contact your gas installer for remedial action to be taken.
Under no circumstances should it be adjusted or put out of action by the installer
or the user. In case the pilot needs replacing, only the approved part (listed in the
spare parts list) should be fitted. Note: if any part of the pilot assembly becomes
faulty the complete assembly will need replacing.
1.2.
1B
Fire Fret Dimensions
All models can be used with the Burley Magiglo range of frets or any other fire fret that
falls within the dimensions shown below
Minimum opening
(free air) in fire fret
Minimum opening
(free air) in ash pan cover
Figure 1
Fire Front Specification
16” Model
18” Model
Height to Centre (A)
Maximum
9 Inches (23cm)
9 Inches (23cm)
Minimum
7.5 Inches (19cm) 7.5 Inches (19cm)
Ash Pan Cover Height (B)
Maximum
3.5 Inches (9cm)
3.5 Inches (9cm)
Minimum
2.5 Inches (6.4cm) 2.5 Inches (6.4cm)
Ash Pan Cover Free Air Opening
Minimum 5
sq.
Inches
(32.3cm
2
)
5 sq. Inches
(32.3cm
2
)
Fire Fret Free Air Opening
Minimum
15 sq. Inches
(97cm
2
)
18 sq. Inches
(116cm
2
)
Ash Pan Cover Length (C)
Maximum
13.5 Inches (34cm) 15.5 Inches (40cm)
Minimum
12.5 Inches (32cm) 14.5 Inches (37cm)
Summary of Contents for ARIA
Page 8: ...Page 4 This page is left intentionally blank...
Page 28: ...Page 24 This page is left intentionally blank...
Page 42: ...Page 38 This page is left intentionally blank...
Page 53: ...Page 49 This page is left intentionally blank...
Page 54: ...Page 50 This page is left intentionally blank...
Page 55: ...Page 51 This page is left intentionally blank...