Page 13
2.3.
4B
Battery Replacement (Optimum Control)
1. The battery pack is mounted inside the
wall-mounting box behind the wall switch
plate.
2. To change the batteries remove the two
small screws securing the wall plate
using a small screwdriver.
3. Remove the battery pack from the wall
box and replace the spent batteries with
new ones (4 off 1.5V AA batteries)
ensuring correct polarity.
4. Insert the battery pack back into the wall
box and refit the wall plate ensuring that
it is the right way up.
5. Secure with screws.
REAR OF WALL
PLATE
CABLE TO
VALVE
BATTERY
PACK
(4 x 1.5 V AA
BATTERIES)
LOW/OFF
SWITCH
HIGH
SWITCH
brown
brown
brown
blue
blue
blue
white
black
Figure 21
2.4.
5B
Battery Replacement (Trim Switch Control)
1. Remove ash pan cover to gain access to
controls.
2. Slide out the battery holder from under
the fire.
3. Replace
all
batteries with new ones (4 x
AA batteries required).
Ensure that the
batteries are inserted with correct
polarity in the holder.
4. Replace the battery holder into the
battery compartment.
5. Return the ash pan cover.
TR AY
FIXING
SCREW
TRAY
FIXING
SCR EW
CONTROL
VALVE
GAS IN LET SL OT
C OVER
GAS
INLET
RECEIVER/
BATTERY
PACK
PILOT
FIXING
SCREWS
HEAT
SHIELD
POWER
SUPPLY
PLUGS
GROMMET
PRESS.
TEST
POINT
Figure 22
CAUTION:
With the exception of battery replacement, the battery holder must be
located within the heat shield
at all times
.
Summary of Contents for ARIA
Page 8: ...Page 4 This page is left intentionally blank...
Page 28: ...Page 24 This page is left intentionally blank...
Page 42: ...Page 38 This page is left intentionally blank...
Page 53: ...Page 49 This page is left intentionally blank...
Page 54: ...Page 50 This page is left intentionally blank...
Page 55: ...Page 51 This page is left intentionally blank...