Boiler is OFF
Short pressing of the
ENTER
turns the boiler ON.
Long pressing of the
ENTER
gets the operator into the parameter settings
Start of the heating
Fan is working with 100% top speed
We can turn OFF the boiler by pressing
ENTER
and
◄
subsequently
After the combustion temperature reaches value
end
+
20°C
in 30 minutes
long time interval the
boiler is in combustion process otherwise the boiler turns off ( END status )
Water pump power ON
Water pump is working in pulse status first and then in permanent status
Boiler is prepared to fuel supply by means of the double pressing of the
ENTER
(
function ) – main fan goes to 100% top speed in suction
version or to 0% in blower version
Combustion
Continuous regulation of the fan keeps the boiler temperature on the acquired
value
Critical values of temperatures and thermostat automatic monitoring
Boiler maximal temperature overrun
Capture of the boiler max. temperature overrun (
T max = T req 10°C
) or
at
Tmax = 90°C
Fan power OFF. Back from MAX state gets boiler after decreasing under the
requested temperature.
Heating gets weaker
Top speed of the fan (100%) cannot reach requested temperature for long time
Combustion temperature falls despite the top speed (100%) of the fan for long
time
Fuel supply is necessary
Fuel supply
Double click of the button
ENTER
( function
) prepares the boiler to fuel
supply– main fan goes to 100% top speed in suction version or to 0% in blower version
Door opening
Basic Modes
AK6000.X