3-42
[7] CHECKING/REFILLING BATTERY ELECTROLYTE LEVEL
• The electrolyte generates combustible gas and presents explosion hazard. Do not bring any
fire close to the electrolyte.
• The electrolyte is a hazardous substance. Avoid contact with eyes or skin. Should it come into
the contact with eyes or skin, wash the affected area with plenty of water and consult a
physician.
• Do not refill the electrolyte above the “Maximum level line”.
The fluid leakage can cause fire.
CAUTION
• Wipe the top of the battery with moistened cloth to keep it clean.
• Distilled water should be refilled before starting the work next day to avoid freezing.
[LEVEL CHECK]
1. Stop the machine on a level surface.
2.
See “Operation 2.13 Outrigger Set Up Operation” to rotate the
outrigger rotary of the
“outrigger (3)” and “outrigger (4)” outward.
3. Verify the electrolyte you can see through the side of the battery
case from the inspection hole of the machinery cover.
NOTES
Wipe the battery case clean if it is dirty.
4. Verify that the surface of the electrolyte is at the upper level line
(1).
5. When the electrolyte is at the upper level line (1),
see “Operation
2.23 Outrigger Stow
ing Operation” and rotate the outrigger
rotary of the “outrigger (3)” and “outrigger (4)” inward and stow.
[REFILLING WITH ELECTROLYTE]
If the surface of the electrolyte is not at the maximum level line (1),
refill with the distilled water using the following procedure.
1. See
“Operation 1.6 Machinery Cover” to remove the machinery
cover.
2. Remove the wing nut (4) and remove the rod (5) and battery
holder (3).
Summary of Contents for MC-174CRM
Page 2: ......
Page 8: ...0 6...
Page 60: ...2 38 31 Precautions for use portable card 101 2141000...
Page 62: ...2 40...
Page 77: ...3 15...
Page 117: ...3 55 5 Push the choke knob forward to return the original position...
Page 195: ...4 23...
Page 197: ...4 25...
Page 214: ...5 4 2 OVERALL DIMENSIONS...
Page 215: ...5 5 3 OUTRIGGER SPREAD DIMENSIONS...
Page 219: ...5 9 5 WORKING RANGE...
Page 220: ...5 10...