DMX 1 -> Art-Net and DMX 2 -> Art-Net specify if the corresponding XLR port is used for DMX-IN
and if those incoming values should be broadcasted to the Art-Net network and to which Art-Net
universe it should be sent. You can use this option to control the MADRIX software remotely, for
example. You would connect an external unit to the PLEXUS to an XLR port (using DMX-IN) and
send the incoming data over network to the MADRIX PC. The MADRIX PC could receive these Art-
Net Remote commands and the software can be controlled remotely (Art-Net Remote). For
example, you could use a lighting console to control individual faders of the software.
DMX-IN input will be send over Art-Net to the configured Art-Net universe via Broadcast according
to the configured IP address and Subnet mask of the device.
You may change the settings in this menu, on the device (
).
You can also configure the settings in the PLEXUS Configuration dialog using MADRIX. For more
information, see
.
Configuring Art-Net-Remote in MADRIX
Activating Art-Net
In MADRIX, navigate to the menu
'Preferences' 'Device Manager'
(or press
'F4'
). Select the
tab
'Art-Net'
.
Enable Art-Net here by
activating the check-box
in the upper left corner.
If you have enabled Art-Net inside this dialog, you will see at least one entry. The
'Art-Net
Remote'
entry is automatically provided by MADRIX and you can use it for controlling MADRIX
remotely within the Art-Net network (Art-Net Remote).
MADRIX supports only one "ArtNet Remote" device.
Summary of Contents for PLEXUS
Page 4: ...Part I...
Page 29: ...MADRIX PLEXUS User Manual English 29 2013 inoage GmbH Using A Port As Digital Output...
Page 30: ...MADRIX PLEXUS User Manual Handbuch 30 2013 inoage GmbH Using A Port As Digital Input...
Page 31: ...MADRIX PLEXUS User Manual English 31 2013 inoage GmbH Using Light Diodes...
Page 32: ...MADRIX PLEXUS User Manual Handbuch 32 2013 inoage GmbH Using A Port As Analog Input...
Page 147: ...Part II...
Page 175: ...MADRIX PLEXUS Handbuch Deutsch 175 2013 inoage GmbH Allgemeine technische Daten...
Page 177: ...MADRIX PLEXUS Handbuch Deutsch 177 2013 inoage GmbH Benutzung eines Ports als Digital Input...
Page 178: ...MADRIX PLEXUS User Manual Handbuch 178 2013 inoage GmbH Benutzung von Leuchtdioden...
Page 179: ...MADRIX PLEXUS Handbuch Deutsch 179 2013 inoage GmbH Benutzung eines Ports als Analog Input...
Page 238: ...MADRIX PLEXUS User Manual Handbuch 238 2013 inoage GmbH Weiter zu 6 Schritt...