3.2 - GT944 SELF-POWERED SIREN CONNECTIONS
1 -
Check that the switch No. 6 is in the OFF position and No. 7 is in the ON position (GT944 SIREN
ENCODED OUTPUT).
2 -
Connect the
BROWN
wire (Negative main power supply) to the negative battery pole.
3 -
Connect the
RED
(Positive main power supply) wire to the positive battery pole via a 5 A fuse.
4 -
Connect the
BLUE
siren wire to the YELLOW/BLACK wire of the alarm control panel.
5 -
Connect the
GREEN
wire to the hood button of the vehicle or to an additional one. Do not connect
this wire if the BONNET protection is available on the CAN BUS line of the vehicle (see vehicle data
sheet). Factory set for stable negative signals. If connected to the original vehicle buttons with
negative impulsive signals (polling) carry out the following procedure:
A - Close the hood and then place the control unit in Quick Test mode.
B - Wait 10 seconds and exit Quick Test mode.
3.3 – SELF-POWERED SIREN CONNECTIONS "VIA RADIO" GT945
1 -
Connect the
BROWN
wire (Negative main power supply) to the negative battery pole.
2 -
Connect the
RED
(Positive main power supply) wire to the positive battery pole via a 5 A fuse.
3 -
Connect the
GREEN
wire to the hood button of the vehicle or to an additional one. Do not connect
this wire if BONNET protection is available on the CAN BUS line of the vehicle (see vehicle data sheet).
Factory set for stable negative signals. If connected to the original vehicle buttons with negative
impulsive signals (polling) carry out the following procedure:
A - Close the hood and then place the control unit in Quick Test mode.
B - Wait 10 seconds and exit Quick Test mode.
6
En
Summary of Contents for GT ALARM GT1006CB
Page 1: ...GT1006CB GT1007CB GT1008CB GT1009CB MANUALE D INSTALLAZIONE Italiano...
Page 27: ...GT1006CB GT1007CB GT1008CB GT1009CB INSTALLATION MANUAL English...
Page 35: ...5 RECEPTACLE CONNECTION DIAGRAM CONTROL LED GT1001CB B GT949 8 En...
Page 36: ...6 CONNECTION DIAGRAM GT1001CB B GT949 GT SATELLITE ALARM SYSTEM 9 En...
Page 37: ...7 GT949 CENTRAL CLOSURES CONNECTION DIAGRAM 10 En...
Page 53: ...GT1006CB GT1007CB GT1008CB GT1009CB MANUEL D UTILISATION ET D INSTALLATION Fran ais...
Page 63: ...7 SCH MA DE RACCORDEMENT DES FERMETURES CENTRALIS ES GT949 11 Fra...