Any compatible open center hydraulic power supply that supplies 2-8 gpm and up to 
2000 psi is acceptable for use with the LL-1.  Be sure that the hydraulic flow direction 
of the power unit matches the in and out labels on the control valve on the LL-1FPM 
10 Ton Jack Assy. Reversed flow is a common problem and the jack will not extend 
or retract when the control valve handle is shifted.    

Caution: LL-1FPM jack assembly is a double acting jack designed to be operated with 
hydraulic power sources capable of 2000 psi maximum and 2 

– 8 gpm. If other power 

sources are used, then the user does so at their own risk and it is highly recommended 
that the user consult with a professional hydraulic supplier to determine the 
combination is safe and that the bypass valve on the LL-1FPM is properly set.   
 

 

 

 

 

TROUBLE SHOOTING 

  

Symptom, Probable Cause & Remedy 

  

Cannot connect hydraulic couplers:

 Trapped pressure 

– see paragraph  11 

TRAPPED PRESSURE  
  

Jack does not extend: 

If the hydraulic flow not activated on power source, turn on 

the flow.  
 

Hydraulic flow direction backwards

: Check that the pressure port from hydraulic 

power supply is mated to the port on the LL-

1FPM Valve labeled “IN”, and the return 

(tank) port on the power source is mated to the port on the Valve labeled “OUT”.  
See Drawing #50141 Sheet 1 of 2 for location of the port labels on the valve.   

  

Jack does not achieve required load, but anchor is not moving:

 Hydraulic flow 

from power unit is too low. Open throttle on the power source to achieve a higher 
flow rate. If this does not solve the problem, then readjust the bypass valve. This is a 
common problem with alternate low flow rate power rate units.  
  

Gauge reads 4000lb load with valve handle in neutral position, but there is no 
load on anchor:

 This is a characteristic of the hydraulic design of the control valve 

called trapped back pressure. Back pressure from hydraulic flow is trapped on both 
sides of the jack piston and registers on the gauge when the valve is shifted into the 
neutral position. It does not affect the accuracy of the gauge reading if the 
recommended method of proof testing is followed. The phenomenon manifests itself 
to a greater degree at higher flow rates like 5- 8 gpm and is very evident when the 

Summary of Contents for Manta Ray LL-1

Page 1: ...P 855 MPS SHIP macleanpower com 481 MUNN RD SUITE 300 FORT MILL SC 29715 LL 1 Anchor Locking Kit Operating Manual Summer 2020 ...

Page 2: ...LL 1FPM 50250 5 32 Hex Driver For adjustment of the Bypass Valve on LL 1FPM 51188 Refer to Drawing E1012 A Page 1 for a pictorial view The Anchor Locking Kit does not include a hydraulic power supply or hydraulic hoses These must be supplied separately The following power units and hoses are designed to power the LL 1 and are available from your Manta Ray Distributor 50382 GPU18 8 CE 18 HP 8 gpm 2...

Page 3: ...alve is in the neutral position If it is desired to hold a constant load then the valve handle must be held in the open position for the duration of the load hold See paragraph 7 RECOMMENDED PROOF TEST METHOD HYDRAULIC RATING HTMA type II HYDRAULIC SAFETY The Control valve on the LL 1FPM 10 ton jack assembly contains a simple hydraulic bypass valve that limits the maximum hydraulic pressure to saf...

Page 4: ...he Adapter setting bar and securely into the tapered top of the LL 1FPM Jack assembly 5 Connect the hydraulic hoses between the hydraulic power supply and the LL 1FPM Jack assembly See paragraph 11 TRAPPED PRESSURE OPERATION CAUTION The LL 1 Anchor Locking Kit is capable of pulling with forces up to 20000 pounds The following precautions must be taken 1 Never apply more than 2000 psi to the unit 2...

Page 5: ... This is called topping out When the jack tops out the load indication on the gauge will increase rapidly to the bypass setting this is a false indication Retract the jack by pulling the valve handle away from the body The tapered Jaws should release by themselves If they do not release tap the side of the tapered top of the jack with a hammer Fully retract the jack Lubricate the outside of the Ta...

Page 6: ...bly on the floor bench or ground without the base plate tapered jaws or adapter setting bar 2 Connect the jack to the same hydraulic power source that will be used in service for locking anchors 3 Start the hydraulic power source and set the throttle at the same position that will be used in service 4 Extend the jack to the top of its stroke Keep the control valve shifted fully to the extend posit...

Page 7: ...aulic flow not activated on power source turn on the flow Hydraulic flow direction backwards Check that the pressure port from hydraulic power supply is mated to the port on the LL 1FPM Valve labeled IN and the return tank port on the power source is mated to the port on the Valve labeled OUT See Drawing 50141 Sheet 1 of 2 for location of the port labels on the valve Jack does not achieve required...

Page 8: ...raulic tools and couplers The three most common sources of trapped pressure are 1 Failure to relieve any trapped back pressure in the tool circuit prior to uncoupling hoses from tools This is avoided by cycling the tool control valves on and off up and down extend and retract etc several times after turning off the hydraulic flow from the power unit but prior to uncoupling 2 Sunlight heating hoses...

Page 9: ...wing 50141 3 Sometimes repeated cycling of the control valve on the LL 1 FPM will reduce the pressure enough to force couplers together 4 Sometimes repeated attempts to connect a coupler will allow enough fluid to leak out that the connection can be made SPARE PARTS Spare parts for the LL 1 Anchor Locking kit are available from your Manta Ray distributor Refer to Drawing E1012 for the major compon...

Page 10: ...P 855 MPS SHIP macleanpower com 481 MUNN RD SUITE 300 FORT MILL SC 29715 ...

Page 11: ...P 855 MPS SHIP macleanpower com 481 MUNN RD SUITE 300 FORT MILL SC 29715 ...

Page 12: ...P 855 MPS SHIP macleanpower com 481 MUNN RD SUITE 300 FORT MILL SC 29715 1 16 2 14 15 5 14 15 17 4 4 4 6 2 4 7 9 7 8 12 11 5 10 4 18 13 6 ...

Reviews: