34
·
Operation Instruction of S900 E Series Inverter
·
35
·
Function
Parameters
Name
Setting Range
Minimum
Setting
increments
Initial value
Refer
To
Page
Secondary application
P400
Jog frequency
setting
0.00~maximum
frequency
0.01
5.00
80
P401 Acceleration
time 2
0~999.9s
0.1S
10.0
81
P402 Deceleration
time 2
0~999.9s
0.1S
10.0
81
P403 Acceleration
time 3
0~999.9s
0.1S
20.0
81
P404 Deceleration
time 3
0~999.9s
0.1S
20.0
81
P40 5
Acceleration
time 4/Jog
acceleration
time
0~999.9s
0.1S
2.0
81
P406
Deceleration
time 4/Jog
deceleration
time
0~999.9s
0.1S
2.0
81
P407
Designated
value of
counter
0~999.9s
1
100
81
P408
Intermediate
value of
counter
0~999.9s
1
50
81
P409
Limitation of
acceleration
torque
0~200%
1%
150%
81
P410
Limitation of
constant speed
torque
0~200%
1%
00
82
P411
Over voltage
prevention
selection in
deceleration
0/1
1
1
82
P412
Automatic
Voltage
regulation
selection
0~2
1
1
83