22
MAC 6000 Hydronic Heater
2106 East Indiana Ave., Bismarck, ND 58504 U.S.A. • www.macheaters.com • +1-800-272-4604
Start/Stop Procedure
MAC 6000
2106 East Indiana Ave., Bismarck, ND 58504, U.S.A. www.macheaters.com +1.800.272.4604
Page 24
START/STOP PROCEDURE
3
4
6
Engine/Heater Control Panel
START PROCEDURE
1. Perform pre-start and engine compartment checklists.
2. Hook up and layout your ground hoses in desired configuration.
3. Turn battery disconnect connect switch to “ON” position.
4. Turn ignition key to “Run” position until glow plug indicator light expires
.
5. Turn ignition key to “Start” position until engine starts, then release ignition
key.
6. Turn main circuit breaker to “ON” position, located on the power distribution
panel.
7. Select heater performance output.
a. Select desired output temperature on the heater controller by using the
up and down arrow keys.
b. Press “OK” button to engage heater.
c. Heater will automatically enter a “Warm Up” mode.
d. Once “Warm Up” mode has been completed heater will function
normally.
STOP PROCEDURE
1. Press “OK” button on controller to shutdown heater.
a. Failure to shutdown heater before turning off generator could result in
damage to the heater.
2. Turn main circuit breaker to “OFF” position.
3. Turn ignition key to “OFF” position.
4.
Caution:
Allow hot ground hoses to cool before handling and preparing for
storage. Hot ground hoses can cause severe burns.