DISASSEMBLY
Impeller Cap
With a thin flat screwdriver remove the Impeller Cap, be
careful not to mistreat it.
Impeller Screw
Remove the Impeller Screw using a 7/16” socket. It is
recommended that the Infuser Screw be replaced each
time it is removed for Service and should be torqued to
100 +/- 5 lbs. In.
Impeller
If the Impeller is stuck. it is recommended to use hot water
and a belt underneath the Impeller or it is recommended
to use an extractor as described below, it is recommended
to place a little bit of WD-40 5 minutes before use it.
Impeller extractor.
Install the Extractor Screw
Place the hooks or rods of the extractor in the 2 slots of
the Impeller.