55
|
Manual de Servicio
Ingenieria de Servicio
3
t3
Softener valve (Applies for
models with Dispenser)
(led "spin" + "rinse")
X
Turn on valve during test (Auto-off in 60s)
4
t4
Chlorine valve
NA
Turn on valve during test (Auto-off in 60s)
5
t5
Drain pump /
Thermoactuator / Lid Lock
(led "
spin " + "wash")
X
Turn on drain pump, switch to Spin mode and spin,
lock the lid
6
t6
Drain pump
(led "rinse" + "wash")
X
Turn on drain pump during test
7
t7
Lid Lock
NA
Lock the lid
8
t8
Pressure sensor
(led "eco")
X
If the control board detects correct sensor
operation, it activates the valves and fills until it
reaches 2 inches of water.
The test ends successfully when this level is
reached.
The display shows the water column value
(example 1.5in H2O, shows 15)
On models with Knobs, 1 LED will light for every
0.5"
9
t9
Speed Sensor / TRIACS
(“
eco
” + “
spin
” led)
X
A shaking pattern is performed in both directions
to validate the reading of speed sensor pulses and
operation of triacs
10
tA
Lid Switch
(led "eco" + "rinse")
X
The control board shows the status of the lid on
the display and with LEDs:
Open lid:
"LO" on display
Summary of Contents for Centauro CLGG70214 Series
Page 44: ...44 Manual de Servicio Ingenieria de Servicio Modelos Eléctricos 127V DIAGRAMA ELÉCTRICO ...
Page 45: ...45 Manual de Servicio Ingenieria de Servicio Modelos Eléctricos 220V DIAGRAMA ELÉCTRICO ...
Page 71: ...71 Manual de Servicio Ingenieria de Servicio GARANTIA ...
Page 72: ...72 Manual de Servicio Ingenieria de Servicio ...
Page 113: ...41 Manual de Servicio Ingenieria de Servicio CONTROL BOARD ...
Page 115: ...43 Manual de Servicio Ingenieria de Servicio Electric Models 220V ELECTRIC DIAGRAM ...