57
|
Manual de Servicio
Ingenieria de Servicio
DRYER
BASIC OPERATION
ELECTRIC DRYER
➢
Airflow passes from outside the cabinet and enters
the Dryer.
➢
The Rear Panel has openings and grilles for air intake.
➢
Inside, the air passes through the electrical heater
heating up.
➢
The hot air enters the drum to evaporate the water in
the clothes.
➢
The steam passes through the lint trap into the trap
duct, pulling it out of the drum.
➢
Finally, exit the system through the exhaust.
➢
The Electric Dryer has 2 power levels.
FUNCIONAMIENTO BASICO
SECADORA A GAS
➢
Airflow passes from outside the cabinet and enters
the Dryer.
➢
The Rear Panel has openings and grilles for air intake
➢
Inside, the air is heated by means of gas combustion
in the combustion chamber.
➢
A mixture of cool and hot air is made inside before
passing through the gas diffuser.
➢
The hot air enters the drum to evaporate the water in
the clothes.
➢
The steam passes through the lint trap into the trap
duct, pulling it out of the drum.
➢
Finally, exit the system through the exhaust.
➢
The Gas Dryer has 1 power level.