![M-system SC100 Series User Manual Download Page 19](http://html1.mh-extra.com/html/m-system/sc100-series/sc100-series_user-manual_3126159019.webp)
19
SCCFG Users Manual EM-9192 Rev.4
6.7 CONFIGURATION ITEM LIST
ITEM
SUB ITEM
DATA
DEFAULT
CONTENTS
Back light brightness
1, 2, 3, 4, 5
5
Backlight brightness control
Screen saver (time)
0, 1 – 99 minutes
0 (OFF)
Time before the screen turns off when not ac-
cessed.
Screen saver does not turn on when:
- PV high or low alarm is tripped.
- ALM1, ALM2, ALM3 or ALM4 is indicated.
- The device is in an abnormality.
- Engineering view is on the screen.
MV-0/100% symbol
MV1 100% symbol
O, C, OP, CL
O, C, OP, CL, HI, LO,
100, 0, MIN, MAX,
None
OP
Mv 1 / Mv 2 graph scale 0% and 100% symbols
MV1 0% symbol
CL
MV2 100% symbol
OP
MV2 0% symbol
CL
Loop display (MV/OP)
LP1 display (MV)
1, 2
1
Mv signal assigned to the primary loop view.
LP2 display (MV)
2
Mv signal assigned to the secondary loop view.
Loop variables
PV/SP/MV, SV/PV/OP PV/SP/MV
Variables assignment (order) for bargraphs
(SV=SP, OP=MV)
Graph scale divisions
2 – 10
10
Number of divisions applied to graphs on Bar-
graph view
Decimals (% display)
1, 2
1
Number of decimal places applied to % indica-
tion (PV1, PV2, SP1, SP2, MV1, MV2)
Alarm blinking
Disable, Enable
Enable
Digital displays can be set to blink during PV
and/or MV alarms.
Bargraph color
PV1 norm
18 colors
(color chart)
*
1
5
PV1 bargraph color, normal range
PV1 Hi
1
PV1 bargraph color, high alarm range
PV1 Lo
4
PV1 bargraph color, low alarm range
PV2 norm
5
PV2 bargraph color, normal range
PV2 Hi
1
PV2 bargraph color, high alarm range
PV2 Lo
4
PV2 bargraph color, low alarm range
SP1 norm
8
SP1 bargraph color, normal range
SP2 norm
8
SP2 bargraph color, normal range
MV1 norm
13
MV1 bargraph color, normal range
MV1 Hi
12
MV1 bargraph color, high alarm range
MV1 Lo
14
MV1 bargraph color, low alarm range
MV2 norm
13
MV2 bargraph color, normal range
MV2 Hi
12
MV2 bargraph color, high alarm range
MV2 Lo
14
MV2 bargraph color, low alarm range
Digital display color
PV1
18 colors
(color chart)
*
1
16
Digital display color (PV1, PV2, MV1, MV2,
SP1, SP2, FN1, FN2, FN3, FN4)
(High/Low alarm colors specified for bargraphs
are applied.)
PV2
SP1
SP2
MV1
MV2
FN1
FN2
FN3
FN4
Trend recording
Start, Stop
Start
Trend recording operation control
Storing interval
1 sec thr. 60 min
10 sec
Short trend storing interval
*
2
(1, 2, 5, 10, 20, 30 sec, 1, 2, 5, 10, 30, 60 min)
Trend channel
LP1 CH1
None, PV1, PV2,
SP1, SP2, MV1, MV2,
FN1, FN2, FN3, FN4
PV1
Short trend channel assignment (CH1 thr. CH4)
LP1 CH2
SP1
LP1 CH3
MV1
LP1 CH4
None
LP2 CH1
PV2
LP2 CH2
SP2
LP2 CH3
MV2
LP2 CH4
None