R7HL-DC16B

EM-7812-H  Rev.4  P. 3 / 5

 

OUTPUT TERMINAL ASSIGNMENT

10

+24V

11

Y1

12

Y3

1

0V

2

Y0

3

Y2

13

Y5

4

Y4

14

Y7

5

Y6

15

Y9

6

Y8

16

YB

7

YA

17

YD

8

YC

9

YE

18

YF

NO.

ID

FUNCTION

NO.

ID

FUNCTION

1

0V

0V

10

+24V

24V DC (common)

2

Y0

Output 0

11

Y1

Output 1

3

Y2

Output 2

12

Y3

Output 3

4

Y4

Output 4

13

Y5

Output 5

5

Y6

Output 6

14

Y7

Output 7

6

Y8

Output 8

15

Y9

Output 9

7

YA

Output 10

16

YB

Output 11

8

YC

Output 12

17

YD

Output 13

9

YE

Output 14

18

YF

Output 15

TERMINAL CONNECTIONS

Connect the unit as in the diagram below.

 

EXTERNAL DIMENSIONS  unit: mm (inch)

4

5

6

7

1

2

3

10 11 12 13

2

3

4

1

15 16 17 18

7

8

9

6

14

5

DIN RAIL

35mm wide

54 (2.13)

17 (.66)

115 (4.53)

[5 (.20)]

30 (1.18)

3 (.12)

5.5 (.22)

50 (1.97)

18.5 (.73)

7–M3 SCREW

TERMINALS

for Network, POWER

18–M3 SCREW 

TERMINALS

for OUTPUT

6 (.24)

6 (.24)

056 222 38 18

[email protected]

www.sentronic.com

SENTRONIC

AG

Summary of Contents for R7HL-DC16B-R

Page 1: ...n regard to the whole system and employ additional protective measures to ensure the CE conform ity POWER INPUT RATING OPERATIONAL RANGE Locate the power input rating marked on the product and confirm its operational range as indicated below 24V DC rating 24V 10 approx 45mA GENERAL PRECAUTIONS Before you remove the unit or mount it turn off the power supply and output signal for safety DO NOT set ...

Page 2: ...s Setting x1 Station Address Setting x16 0 1 2 3 4 5 6 789A B C D E F 0 1 2 3 4 5 6 789A B C D E F OPERATING MODE Factory setting Output at the loss of communication SW1 7 SW1 7 OUTPUT AT THE LOSS OF COMMUNICATION OFF Hold the output maintains the last data received normally ON Reset the output turned off Transfer rate SW1 8 SW1 8 TRANSFER RATE OFF 12 Mbps ON 6 Mbps Note Be sure to set unused SW1 ...

Page 3: ...14 Y7 Output 7 6 Y8 Output 8 15 Y9 Output 9 7 YA Output 10 16 YB Output 11 8 YC Output 12 17 YD Output 13 9 YE Output 14 18 YF Output 15 TERMINAL CONNECTIONS Connect the unit as in the diagram below EXTERNAL DIMENSIONS unit mm inch 4 5 6 7 1 2 3 10 11 12 13 2 3 4 1 15 16 17 18 7 8 9 6 14 5 DIN RAIL 35mm wide 54 2 13 17 66 115 4 53 5 20 30 1 18 3 12 5 5 22 50 1 97 18 5 73 7 M3 SCREW TERMINALS for N...

Page 4: ...is NOT a protective conductor terminal WIRING INSTRUCTIONS SCREW TERMINAL Torque 0 5 N m SOLDERLESS TERMINAL Refer to the drawing below for recommended ring tongue terminal size Spade tongue type is also applicable Recommended solderless terminal Communication cables Applicable wire size 0 2 to 0 5 mm2 AWG 26 to 22 Recommended manufacturer Japan Solderless Terminal MFG Co Ltd Others Applicable wir...

Page 5: ...odule TR TR FG SHIELD Slave Module TR TR SHIELD Note Be sure to turn ON the switch of the terminating resistor located at both ends of the modules Terminating Resistor Terminating Resistor MASTER CONNECTION Full duplex communication Half duplex communication I O DATA DESCRIPTIONS DISCRETE OUTPUT Unused 0 15 0 15 Di Do Output 0 Output 1 Output 2 Output 3 Output 15 Output 7 Output 8 0 OFF 1 ON 056 2...

Reviews: