MB-RAD
Seite 9
•
The limits are confirmed with the (M) button.
•
The limits are also stored when storing as a preset.
•
In the event that the limits are not met or are exceeded when operating, an
indicator appears on the screen.
•
The torque wrench can be operated again after pressing any button.
5.12.
Bolt counter
•
The bolt counter is activated and deactivated in advanced settings:
•
The bolt counter is set on the main screen:
•
Once activated, the bolt counter must be set to a minimum of 1 and can be set
to a maximum of 999.
•
The bolt counter counts all completed bolting operations in a clockwise direction.
Counter clockwise will be ignored.
•
Once all bolts have been tightened, the device is locked. The device can be released
in two ways:
·
Resetting the number of individual bolts.
·
Deactivating the bolt counter.
•
If the battery is removed from the torque wrench before the bolt counter is
complete, the counter will resume from the same point the next time the torque
wrench is used.
•
To prevent the individual bolts from being torqued twice, e.g. by tightening a bolt
that has already been tightened (“rehit”), the counter should be used in combination
with the limit setting. For instance a minimum Angle must be achieved to count as a
correct tightening.