‘Accept’ applies the displayed preset as the current setting.
•
‘Overwrite’ will store the pre
set settings in the current preset.
•
To save a preset, first enter the desired torque (+ angle) in the
main screen.
•
‘Cancel’ returns you to the displayed preset.
•
‘Back’ returns you to the presets menu.
•
'Back’ returns to the presets menu of
the main menu.
•
HV preset can only be selected and cannot be overwritten.
•
HV preset are displayed only in accordance with the torque range of the torque
wrench.
•
The preset tightening torques for HV bolts refer to the modified torque procedure in
accordance with DIN EN 19963-1-8 for k-class K1.
5.11.
Limit settings
•
Limits are activated and deactivated in advanced settings:
•
Limits can be defined for every final torque.
•
Angle limits can be defined for purely torque-controlled tightening. The angle
is counted when the torque wrench’s minimum torque is reached and will only be
measured after the tool has reached its minimum torque.
•
Limits can be defined for the final tightening torque for torque/angle tightening.
•
The limits are entered on the main screen after the torque and angle have been set: