M Design LUNA HC Series Instructions For Installation And Use Manual Download Page 2

2

 

 

 

Attention 

:  

THE SUPPLIER TAKES NO RESPONSIBILITY FOR ANY POSSIBLE DAMAGE, POWER LESS 

WORKING APPLIANCES DUE TO ACCIDENT AS A RESULT OF INCORRECT INSTALLATION. 

 

SUMMARY 

1

 

GENERAL .................................................................................................................................................. 3

 

1.1

 

TRANSPORT

 

AND

 

INSTALLATION ........................................................................................................... 3

 

1.2

 

FUEL ....................................................................................................................................................... 3

 

1.2.1

 

Recommended fuel: Wood – hard, soft – damp cca 16% .................................................................. 3

 

1.2.1.1

 

Optimal operation .................................................................................................................................... 3

 

1.2.2

 

Forbidden fuel ................................................................................................................................... 3

 

1.3

 

STARTING

 

THE

 

FIRE ................................................................................................................................ 4

 

2

 

INSTALLATION ......................................................................................................................................... 4

 

2.1

 

INSTALLATION ........................................................................................................................................ 4

 

2.2

 

LIST

 

OF

 

STANDARDS

 

TO

 

BE

 

OBSERVED

 

DURING

 

ASSEMBLY

 

AND

 

OPERATIONS ..................................... 4

 

2.3

 

SAFE

 

DISTANCE

 

FIREPLACE

 

STOVES

 

TYPE

 

„LUNA

 

HC“

 

FROM

 

FLAMMABLE

 

MATERIALS,

  

LOCATION

 

FIREPLACE

 

STOVES

 

AND

 

SMOKE

 

EXTRACT ............................................................................................. 4

 

2.4

 

LOCATION

 

THE

 

FIREPLACE

 

FURNACE

 

TYPE

 

SERIES

 

„LUNA

 

HC“

  

ON

 

THE

 

FLOOR...................................... 5

 

2.5

 

REQUIREMENTS

 

FOR

 

PASSING

 

COMBUSTION

 

AIS ................................................................................. 5

 

2.6

 

INSTALLATON THE FIREPLACE MODEL SERIES „LUNA HC“ ON THE PLACE OF USE

 ................... 5

 

2.7

 

LOCATION

 

FIREPLACE

 

FURNACE ............................................................................................................ 6

 

2.8

 

ISOLATION

 

AND

 

SURROUND .................................................................................................................. 6

 

2.9

 

INSTALLATION

 

OF

 

3-SIDED

 

FRAME......................................................................................................... 7

 

2.10

 

COMBUSTION

 

AIR

 

INTAKES .................................................................................................................... 7

 

2.11

 

VENTILATION ......................................................................................................................................... 7

 

2.11.1

 

Natural convection ........................................................................................................................ 7

 

2.11.2

 

The hot-air distribution ................................................................................................................. 8

 

2.12

 

CHIMNEY................................................................................................................................................ 9

 

3

 

CONTROL ............................................................................................................................................... 10

 

4

 

GENERAL RECOMMENDATIONS ............................................................................................................. 11

 

4.1

 

MAINTANCE ......................................................................................................................................... 11

 

4.1.1

 

CLEANING GLASS ............................................................................................................................. 12

 

5

 

SECURITY CONDITIONS .......................................................................................................................... 12

 

6

 

SUPLIED ACCESSORIES ........................................................................................................................... 13

 

7

 

SIGN ....................................................................................................................................................... 13

 

8

 

SERIE   - SIZE ........................................................................................................................................... 14

 

9

 

SPARE PARTS – LUNA HC ........................................................................................................................ 15

 

10

 

GUARANTEE ........................................................................................................................................... 19

 

10.1

 

TERMS AND ITEMS COVERED .............................................................................................................. 19

 

10.2

 

GUARRANTY

 

CONDITIONS ................................................................................................................... 19

 

 
 

Summary of Contents for LUNA HC Series

Page 1: ...COLLECTION LUNA HC INSTRUCTION FOR INSTALLATION AND USE...

Page 2: ...ALS LOCATION FIREPLACE STOVES AND SMOKE EXTRACT 4 2 4 LOCATION THE FIREPLACE FURNACE TYPE SERIES LUNA HC ON THE FLOOR 5 2 5 REQUIREMENTS FOR PASSING COMBUSTION AIS 5 2 6 INSTALLATON THE FIREPLACE MODE...

Page 3: ...e optimal function of the stove output clear glass etc The ideal is to use dried wood with moisture content 12 to 18 Damp wood gives off less heat clogs the chimmey and the glass of the fireplace s do...

Page 4: ...ibes rules and local regulations The device must be built in an area with an adequate capacity on on the board which can spread the weight of the device The device must be positioned so as to maintain...

Page 5: ...qualified person to deliver state of the chimney and flue for their safe and reliable operation 2 4 LOCATION THE FIREPLACE FURNACE TYPE SERIES LUNA HC ON THE FLOOR In the place of installation firepla...

Page 6: ...INSTRUCTIONS QUIPMENT MAY OVERHEAT Once installation is omplete the device may be doing the surround If you check everything you can to make a final insulating and finishing operations Make sure the d...

Page 7: ...N AIR INTAKES Any type of combustion using air If enclosure is an additional air supply is very important It is very important always to avoid creating negative pressure inside the room Need air intak...

Page 8: ...red to be in the room does not produce any vacuum Grid in the floor sucking cold air pic 12 Do not connect it through a tube The air itself will find a way to get to the right place If it is possible...

Page 9: ...andard diameters In this case refer to the table for the height of the chimney and by reducing the possibility of reduction Chimney fireplace insert LUNA HC can connect from the top Pic 13a or the bac...

Page 10: ...controls the front bar see pic 14a by help of key pic 14b By controllin the flow of air to control your heater secondary primary pic 15 Open the door control doees not affect the combustion Pic 14b Pi...

Page 11: ...nd then bursts when the fire start 4 1 MAINTANCE in addition to regular cleaning of glass must be your chimney at least once a year sweep to insert optimal function It s not just a legal requirement b...

Page 12: ...ation When operating the fireplace furnace type series LUNA rise to the surface of the walls of high temperature at which it could be burning It is therefore prohibited during the operation touch the...

Page 13: ...e only recommended fuels the appliance is designed for shor term operation serial number see Pic 18 TYPE fireplace 700 HC 900 HC 1100 HC Rated thermal power kW 9 10 11 Average efficiency 78 78 78 Heat...

Page 14: ...14 8 SERIE SIZE...

Page 15: ...15 9 SPARE PARTS Luna HC...

Page 16: ...16 SPARE PARTS Luna HC...

Page 17: ...17 SPARE PARTS Luna HC...

Page 18: ...18...

Page 19: ...s inappropriate improper placement and the inevitable damage caused by the event natural disaster etc 4 The guarranty also does not apply to damages caused indirectly and damage or personal injury cas...