M Design LUNA HC Series Instructions For Installation And Use Manual Download Page 4

4

 

 

1.3

 

STARTING THE FIRE 

 

Regulation at maximum /see pic.14/ 

 

Open the door /pic.2a /. 

 

Put  a bed  of  tinder(paper  or  firelighters)  with  a little  kindling  (small  twigs  or  pieces  of  wood)  in  the 
stove and light the tinder. Let the door a little open /+3cm/, so as chimney effect arose, which helps the 
kindling start the fire. 

 

After the kindling has cought fire and burns well, the logs maybe placed on the fire. When the logs are 
burning, the door can be closed. 

 

NOTE: When a fire is made for the first time, the paint will harden and that give off smoke and a smell, 
which starts after the fire has bourned for about 10 minutes and lasts for about 15 minutes. See to it that 
there is ample ventilation in the room. The combustion chamber should be kept closed except for fuelling 
to prevent entry of gases into the room.  

CAUTION: 
It is not necesarry to overload the fireplace with wood. 1kg dried wood gices a 4kW power. 
Example:  a fireplace  with  80%  return  gives  a power  for  about  3,2kW  for  1kg  dry  wood.  If  you  want 
a power about 6-7kW, it is just enough to put 2kg wood in the fireplace. This is like two normal pieces of 
wood.  We  are  not  responsible  for  the  wrong  use  of  fireplace  and  any  consequence  for  not  following this 
guideline. External surfaces of the stove are hot during operation, which has to be paid due attention to 
avoid an accident burns.  

2

 

INSTALLATION 

2.1

 

 INSTALLATION 

For your own safety and satisfaction, we advise you to entrust specialist with the installation. 

The appliance has 

to  be  installed  according  to  certain  prescribes  rules  and  local  regulations.

  The  device  must  be  built  in  an 

area with an adequate capacity,on on the board, which can spread the weight of the device. The device must be 
positioned  so  as  to  maintain  the  safety  distance  from  any  flammable  materials  that  could  not  fire.  However,  if 
you decide to carry out the work on your own, we advise you to do the following: 

 

Refer to the terms and conditions of our contract of guarantee 

 

Ask your supplier for advice. 

2.2

 

 LIST OF STANDARDS TO BE OBSERVED DURING ASSEMBLY AND 
OPERATIONS  

The  fireplace  type  „LUNA  HC“  complies  with  STN  EN  13229.  For  installation  and  operation  of  the 
fireplace type „LUNA HC“ should proceed in accordance with STN 92 0300 „Local fire safety appliances 
and heat sources“ and STN 73 4201 „The design of chimneys and flues“. 

 

2.3

 

 

SAFE DISTANCE FIREPLACE STOVES TYPE „LUNA HC“ FROM FLAMMABLE 

MATERIALS,  LOCATION FIREPLACE STOVES AND SMOKE EXTRACT 

 

Fireplace  type  series  „LUNA  HC“  must  be  installed  in  accordance  with  Decree    MV  SR  No.  95/2004 
statute, coll establishing specifications and requirements for fire safety during instalations and operation of 
heating appliances, electrothermal appliances and central heating installations and the constructions and use 
of chimneys and flues. I tis also necessary to respect the STN 73 4210 „Running of the chimneys and flues 
and  connecting  fuel  appliances.“  The  manufactorer  recommends  the  installattion  of  the  fireplace  furnace 
type series „LUNA HC“ conducted by qualified Professional  who is responsible  for the  material used for 
installation. The manufactorer is responsible for the delivered product. 

 

 

When installing the fireplace type series „LUNA HC“ must be complied  with 1000 mm safety  clearance 
from combustible materials.  
 
 

 

Summary of Contents for LUNA HC Series

Page 1: ...COLLECTION LUNA HC INSTRUCTION FOR INSTALLATION AND USE...

Page 2: ...ALS LOCATION FIREPLACE STOVES AND SMOKE EXTRACT 4 2 4 LOCATION THE FIREPLACE FURNACE TYPE SERIES LUNA HC ON THE FLOOR 5 2 5 REQUIREMENTS FOR PASSING COMBUSTION AIS 5 2 6 INSTALLATON THE FIREPLACE MODE...

Page 3: ...e optimal function of the stove output clear glass etc The ideal is to use dried wood with moisture content 12 to 18 Damp wood gives off less heat clogs the chimmey and the glass of the fireplace s do...

Page 4: ...ibes rules and local regulations The device must be built in an area with an adequate capacity on on the board which can spread the weight of the device The device must be positioned so as to maintain...

Page 5: ...qualified person to deliver state of the chimney and flue for their safe and reliable operation 2 4 LOCATION THE FIREPLACE FURNACE TYPE SERIES LUNA HC ON THE FLOOR In the place of installation firepla...

Page 6: ...INSTRUCTIONS QUIPMENT MAY OVERHEAT Once installation is omplete the device may be doing the surround If you check everything you can to make a final insulating and finishing operations Make sure the d...

Page 7: ...N AIR INTAKES Any type of combustion using air If enclosure is an additional air supply is very important It is very important always to avoid creating negative pressure inside the room Need air intak...

Page 8: ...red to be in the room does not produce any vacuum Grid in the floor sucking cold air pic 12 Do not connect it through a tube The air itself will find a way to get to the right place If it is possible...

Page 9: ...andard diameters In this case refer to the table for the height of the chimney and by reducing the possibility of reduction Chimney fireplace insert LUNA HC can connect from the top Pic 13a or the bac...

Page 10: ...controls the front bar see pic 14a by help of key pic 14b By controllin the flow of air to control your heater secondary primary pic 15 Open the door control doees not affect the combustion Pic 14b Pi...

Page 11: ...nd then bursts when the fire start 4 1 MAINTANCE in addition to regular cleaning of glass must be your chimney at least once a year sweep to insert optimal function It s not just a legal requirement b...

Page 12: ...ation When operating the fireplace furnace type series LUNA rise to the surface of the walls of high temperature at which it could be burning It is therefore prohibited during the operation touch the...

Page 13: ...e only recommended fuels the appliance is designed for shor term operation serial number see Pic 18 TYPE fireplace 700 HC 900 HC 1100 HC Rated thermal power kW 9 10 11 Average efficiency 78 78 78 Heat...

Page 14: ...14 8 SERIE SIZE...

Page 15: ...15 9 SPARE PARTS Luna HC...

Page 16: ...16 SPARE PARTS Luna HC...

Page 17: ...17 SPARE PARTS Luna HC...

Page 18: ...18...

Page 19: ...s inappropriate improper placement and the inevitable damage caused by the event natural disaster etc 4 The guarranty also does not apply to damages caused indirectly and damage or personal injury cas...

Reviews: