4
1.3
STARTING THE FIRE
Regulation at maximum /see pic.14/
Open the door /pic.2a /.
Put a bed of tinder(paper or firelighters) with a little kindling (small twigs or pieces of wood) in the
stove and light the tinder. Let the door a little open /+3cm/, so as chimney effect arose, which helps the
kindling start the fire.
After the kindling has cought fire and burns well, the logs maybe placed on the fire. When the logs are
burning, the door can be closed.
NOTE: When a fire is made for the first time, the paint will harden and that give off smoke and a smell,
which starts after the fire has bourned for about 10 minutes and lasts for about 15 minutes. See to it that
there is ample ventilation in the room. The combustion chamber should be kept closed except for fuelling
to prevent entry of gases into the room.
CAUTION:
It is not necesarry to overload the fireplace with wood. 1kg dried wood gices a 4kW power.
Example: a fireplace with 80% return gives a power for about 3,2kW for 1kg dry wood. If you want
a power about 6-7kW, it is just enough to put 2kg wood in the fireplace. This is like two normal pieces of
wood. We are not responsible for the wrong use of fireplace and any consequence for not following this
guideline. External surfaces of the stove are hot during operation, which has to be paid due attention to
avoid an accident burns.
2
INSTALLATION
2.1
INSTALLATION
For your own safety and satisfaction, we advise you to entrust specialist with the installation.
The appliance has
to be installed according to certain prescribes rules and local regulations.
The device must be built in an
area with an adequate capacity,on on the board, which can spread the weight of the device. The device must be
positioned so as to maintain the safety distance from any flammable materials that could not fire. However, if
you decide to carry out the work on your own, we advise you to do the following:
Refer to the terms and conditions of our contract of guarantee
Ask your supplier for advice.
2.2
LIST OF STANDARDS TO BE OBSERVED DURING ASSEMBLY AND
OPERATIONS
The fireplace type „LUNA HC“ complies with STN EN 13229. For installation and operation of the
fireplace type „LUNA HC“ should proceed in accordance with STN 92 0300 „Local fire safety appliances
and heat sources“ and STN 73 4201 „The design of chimneys and flues“.
2.3
SAFE DISTANCE FIREPLACE STOVES TYPE „LUNA HC“ FROM FLAMMABLE
MATERIALS, LOCATION FIREPLACE STOVES AND SMOKE EXTRACT
Fireplace type series „LUNA HC“ must be installed in accordance with Decree MV SR No. 95/2004
statute, coll establishing specifications and requirements for fire safety during instalations and operation of
heating appliances, electrothermal appliances and central heating installations and the constructions and use
of chimneys and flues. I tis also necessary to respect the STN 73 4210 „Running of the chimneys and flues
and connecting fuel appliances.“ The manufactorer recommends the installattion of the fireplace furnace
type series „LUNA HC“ conducted by qualified Professional who is responsible for the material used for
installation. The manufactorer is responsible for the delivered product.
When installing the fireplace type series „LUNA HC“ must be complied with 1000 mm safety clearance