The fireplace type series „LUNA HC“  must be installed so that before it left space on the layout, about 1 x 
1 m. 

 

Basis  respectively  base  under  fireplace  type  series  „LUNA  HC“  must  be  straight  fire  material  and  must 
withstand heat stress. Also, wall and ceiling material, which the fireplace type series „LUNA HC“ may not 
be from combustible materials, respectively should be used for good thermal insulation 

 

Combustion pipe must be fitted to the fireplace chimney`s mounthpiece furnace type series „LUNA HC“ so 
that i tis firmly and tightly connected. 

 

The combustion pipe might be of black respectively stainless steel pipes and elbows. The flue connection must 
be  made  by  the  shortest  route  to  the  flue  by  STN  73  4210.  The  combustion  pipe  should  be  implemented  and 
concolidate in order to be released accidentally or spontaneously. Pipes that are plugged into each other, should 
be  inserted  in  the  direction  of  flow  of  exhaust  gases.  Where  the  flue  passes  through  building  structure,  which 
contains  flammable  materials,  or  surface  modified  flammable  materials  should  be  insulated  to  protect  the 
crossing design and implement in accordance with Decree MV SR No. 95/2004 statute. 

 

Connection  the  combustion  pipe  of  the  furnace  type  series  „LUNA  HC“  can  only  be  the  chimney,  which  has 
been  expertly  tested.  Based  on  expert  examination  of  the  appliance  flue  connection  and  issue  a professionally 
qualified  person  „Certificate  examination  on  implementation  of  the  chimney,  where  a professionally  qualified 
person to deliver state of the chimney and flue for their safe and reliable operation. 

2.4

 

LOCATION THE FIREPLACE FURNACE TYPE SERIES „LUNA HC“  ON THE 
FLOOR 

In the place of installation fireplace insert type series „LUNA HC“ on the floor must be ensured a minimum 

floor  load  1000  kg.m

-2

.  The  floor  before  the  fireplace  insert  type  series„LUNA  HC“  must  be  fire-resistant 

material at a distance of at least 1000 mm from front wall of the fireplace isert type series „LUNA HC“. 

2.5

 

 REQUIREMENTS FOR PASSING COMBUSTION AIS 

The fireplace furnace type series „LUNA HC“can be placed directly in the heated respectively outside 

the heated space. The combustion of fuel used air from the area where is the fireplace furnace, or it is possible to 
transport external admission of air and connect it according to the point 2.10. In case of insufficient ventilation 
of this area is necessary to ensure sefficient fresh air.  

2.6

 

INSTALLATON THE FIREPLACE MODEL SERIES „LUNA HC“ ON THE PLACE 
OF USE 

Fireplace  type  series  "LUNA  HC"  is  installed  in  the  heated  or  outside  of  heated  space.  

For  the  location  of  the  fireplace  insert  type  series  "LUNA  HC"  in  the  heated  space,  the  operator  must  decide 
whether  to  implement  the  distribution  of  heated  air  or  not.  If  the  operator  decides  that  yes,  it  is  necessary  to 
ensure the distribution of heated air from the space garnishment fireplace insert type series "LUNA HC" by flex-
tube  respectively.  through  appropriate  pipes  for  the  heated  air  inlet  temperature  of  150  °  C  to  the  desired 
location. If the operator decides that no heated air is to be exported from the area Converted fireplace insert with 
a hot air diffusers, in order to ensure air circulation.

  

 
 
 
 
 
 
 
 
 
 
 

 

Summary of Contents for LUNA HC Series

Page 1: ...COLLECTION LUNA HC INSTRUCTION FOR INSTALLATION AND USE...

Page 2: ...ALS LOCATION FIREPLACE STOVES AND SMOKE EXTRACT 4 2 4 LOCATION THE FIREPLACE FURNACE TYPE SERIES LUNA HC ON THE FLOOR 5 2 5 REQUIREMENTS FOR PASSING COMBUSTION AIS 5 2 6 INSTALLATON THE FIREPLACE MODE...

Page 3: ...e optimal function of the stove output clear glass etc The ideal is to use dried wood with moisture content 12 to 18 Damp wood gives off less heat clogs the chimmey and the glass of the fireplace s do...

Page 4: ...ibes rules and local regulations The device must be built in an area with an adequate capacity on on the board which can spread the weight of the device The device must be positioned so as to maintain...

Page 5: ...qualified person to deliver state of the chimney and flue for their safe and reliable operation 2 4 LOCATION THE FIREPLACE FURNACE TYPE SERIES LUNA HC ON THE FLOOR In the place of installation firepla...

Page 6: ...INSTRUCTIONS QUIPMENT MAY OVERHEAT Once installation is omplete the device may be doing the surround If you check everything you can to make a final insulating and finishing operations Make sure the d...

Page 7: ...N AIR INTAKES Any type of combustion using air If enclosure is an additional air supply is very important It is very important always to avoid creating negative pressure inside the room Need air intak...

Page 8: ...red to be in the room does not produce any vacuum Grid in the floor sucking cold air pic 12 Do not connect it through a tube The air itself will find a way to get to the right place If it is possible...

Page 9: ...andard diameters In this case refer to the table for the height of the chimney and by reducing the possibility of reduction Chimney fireplace insert LUNA HC can connect from the top Pic 13a or the bac...

Page 10: ...controls the front bar see pic 14a by help of key pic 14b By controllin the flow of air to control your heater secondary primary pic 15 Open the door control doees not affect the combustion Pic 14b Pi...

Page 11: ...nd then bursts when the fire start 4 1 MAINTANCE in addition to regular cleaning of glass must be your chimney at least once a year sweep to insert optimal function It s not just a legal requirement b...

Page 12: ...ation When operating the fireplace furnace type series LUNA rise to the surface of the walls of high temperature at which it could be burning It is therefore prohibited during the operation touch the...

Page 13: ...e only recommended fuels the appliance is designed for shor term operation serial number see Pic 18 TYPE fireplace 700 HC 900 HC 1100 HC Rated thermal power kW 9 10 11 Average efficiency 78 78 78 Heat...

Page 14: ...14 8 SERIE SIZE...

Page 15: ...15 9 SPARE PARTS Luna HC...

Page 16: ...16 SPARE PARTS Luna HC...

Page 17: ...17 SPARE PARTS Luna HC...

Page 18: ...18...

Page 19: ...s inappropriate improper placement and the inevitable damage caused by the event natural disaster etc 4 The guarranty also does not apply to damages caused indirectly and damage or personal injury cas...

Reviews: