6.4 MALFUNCTION, INSPECTION, RESOLUTION PROCEDURE
MALFUNCTION
INSPECTION
RESOLUTION PROCEDURE
No power supplied. LED won‘t
illuminate.
Insuffi cient insertion of Power
Plug into outlet.
Check outlet and securely
connect Power Plug.
No power is supplied
Check power and other rele-
vant parts.
Power Cord is broken.
Arrange its repair or replace-
ment.
Battery Charger‘s power sour-
ce trouble.
Arrange a check or repair.
Receptacle and Plug are im-
properly connected.
Check the connecting parts
and securely connect them.
Battery Pack is improperly
connected
Check the connecting parts
and securely connect them.
Green LED illuminates soon
after the start of charging
Battery is normally charged.
Normal.
Battery malfunction.
Replace with a new Battery.
(See P17.)
The charging process is
completed however workable
period is shortened. .
Battery nearly dead.
Replace with a new Battery.
(See P17.)
Ambient temperature is low
during charging
Charge Battery in an ambient
temperature between 5 and
40°C.
• For safe handling of Charger, be sure to read the instructions
thoroughly before using Charger.
• Charger is only to be used with an AC100-240V power
source. Never connect Power Cable to any other power
source specifi cation.
• Be sure to fi nish trickle charging within 12 hours after
battery charging process is completed. Extended charging
may reduce battery capacity re-suiting in shorter battery life.
• Battery and Charger‘s Output Terminals have polarity.
Confi rm that those Terminals are correctly connected
according their polarity. Improper connection will result in
a short circuit and cause a cable to melt or other serious
charger malfunction.
• Never remove Charger Cover or you will have a danger of
receiving an electric shock.
• Keep Charger indoors, away from direct sunlight and water
splashes, Neglecting this can cause fi re, electric shock or
equipment malfunction.
• As Battery deteriorates, its voltage will fail to reach normal
full-charge voltage.
CAUTION