background image

Analog Ins to ADAT:

When “Analog Ins to ADAT” mode is enabled, the

analog inputs 1 through 8 on your Delta 1010 rack mount unit are routed
through the rack unit’s 24 bit A/D converters to the ADAT Optical output of
the 

Delta 1010-AI

.  Select this mode when you wish to use the A/D converters

on your Delta 1010 rack unit to convert the signal directly to ADAT optical.
This may be desirable if, when doing your recording onto an ADAT, you find
that you prefer using the Delta 1010’s A/D converters.

NOTE: When this mode is selected, the audio outs of the Delta
1010 PCI card are no longer routed to the ADAT Optical out of the
Delta 1010-AI.  This “default” routing is defeated.

ADAT Thru:

When “ADAT Thru” is enabled, the signal present at the ADAT

Optical In of the 

Delta 1010-AI

is routed directly to the ADAT Optical Out.

This mode is desirable when the ADAT input signal must be maintained, or
passed ‘thru’ to the ADAT output. The ADAT Optical in can still be routed to
the Delta 1010 PCI host card and/or the analog outs of the Delta 1010 rack unit.

NOTE: When this mode is selected, the audio outs of the Delta
1010 PCI card are no longer routed to the ADAT Optical out of the
Delta 1010-AI.  This “default” routing is defeated whenever a
different source is selected for the ADAT Optical out (such as
“Analog Ins to ADAT”).

Mixed Modes:

Any combination of 

Delta 1010-AI

modes can be selected, the

results of which can be determined simply by summing the characteristics of
the different modes described in this section.   ADAT Thru mode can be
applied to any of these combinations, with the result as described above, in
“ADAT Thru.”

NOTE: Whenever “ADAT Thru” mode is enabled, the “Analog Ins
to ADAT” mode will be defeated.  Pressing the ‘Analog Ins to
ADAT’ button will have no effect in this case, since this switch
precedes ADAT Thru in the signal path.

Standalone Mode: 

To  use the 1010 rack unit and 

Delta 1010-AI

in

“standalone” mode, your 

Delta 1010-AI

does not need to be connected to your

host computer. When the 

Delta 1010-AI

is connected to the Delta 1010 rack

unit with the rack unit’s power supply properly attached, engaging the power
button on the 

Delta 1010-AI

will trigger the Delta 1010 rack unit to power up.  

When the 

Delta 1010-AI

is not connected to the host computer or the when the

host computer is not powered on, the 

Delta 1010-AI

in standalone mode is

capable of receiving its master clock signal from the ADAT optical input and
communicating this to the Delta 1010 rack unit’s D/A converters.  “ADAT to

9

Summary of Contents for DELTA 1010-AI

Page 1: ...h your Delta 1010 4 Hooking Up Your ADAT Optical Device 5 Using Your Delta 1010 AI 6 ADAT to Host 8 ADAT to Analog Outs 8 Analog Ins to ADAT 9 ADAT Thru 9 Mixed Modes 9 Standalone Mode 9 Master Clock...

Page 2: ...all and configure the Delta 1010 s PCI card Features ADAT I O for PC Windows 95 98 NT Linux and Apple MacOS computers operating up to a full 24 bit 48kHz Provides ADAT record through and playback usin...

Page 3: ...nalog Ins to ADAT Enabled LED When lit this LED indicates that Analog Ins to ADAT mode has been enabled 6 Analog Ins to ADAT Button Pressing this button and locking it to the in position will enable A...

Page 4: ...from the Delta 1010 PCI host card and the Delta 1010 AI Setting up the Delta 1010 AI with your Delta 1010 If you already have your Delta 1010 PCI Recording System installed make sure that you have yo...

Page 5: ...andard for optical cables plugs and jacks Using two good quality TOSLink optical cables 1 Plug one end of an optical cable into the TOSLink optical output jack of your ADAT or other 8 channel ADAT opt...

Page 6: ...10 rack mount unit can also be used in a standalone mode in which the Delta 1010 A D converters send signal directly to the AI s optical output and the Delta 1010 AI optical input connects directly to...

Page 7: ...10 AI in addition to the Delta 1010 analog outs 1 through 8 on the 1010 s rack mount unit by default All other Delta 1010 AI modes are bypassed MIDI I O simply passes through the Delta 1010 AI to the...

Page 8: ...selected from within your music program s audio setup page Once you have opened that page select Wordclock as your master clock source You must also set the Delta control panel to match the sample ra...

Page 9: ...T Optical out of the Delta 1010 AI This default routing is defeated whenever a different source is selected for the ADAT Optical out such as Analog Ins to ADAT Mixed Modes Any combination of Delta 101...

Page 10: ...hen host computer is off or not attached and the Delta 1010 AI is in standalone mode the Delta rack unit s D A comverters will know to get its master clock signal from the ADAT signal at the optical i...

Page 11: ...I O is enabled in the software s MIDI setup page Check your software s documentation You will need to enter a timecode offset into the software s sync setup page also Your BRC may be sending out MTC f...

Page 12: ...roduct requires repair because of user misuse or regular wear it will assess a fair repair or replacement fee The customer will have the option to pay this fee and have the unit repaired and returned...

Reviews: