background image

Analog Outs,” “Analog Ins to ADAT,” and “ADAT Thru” are the modes that
will function independent of the host computer, hence the term “standalone.”

The standalone mode functions are also available when the 

Delta 1010-AI

is

attached to the computer and the computer is powered on.  However, as
described in the “ADAT to Analog Outs” section, the Delta control panel
master clock must be set to “Wordclock” in order for the analog outs to receive
their clock signal from the ADAT optical input.

Master Clock Settings and the Delta 1010-AI

Whenever a valid ADAT 8-channel digital audio signal is present at the

Delta 1010-AI

’s ADAT Optical In and routed to either the host computer’s

Delta 1010 PCI card or Delta rack unit’s analog outs, the system must get its
sampling clock or “wordclock” from that incoming digital signal so that all
digital audio sampling clocks are synchronized.  When the host computer
Delta 1010 PCI card, the 

Delta 1010-AI

, and the Delta rack unit are connected

and powered, the Delta control panel’s “Master Clock” setting in the Hardware
Settings page must be set to “Wordclock” in order for the system will lock to
the incoming digital signal.  When host computer is off or not attached and the

Delta 1010-AI

is in standalone mode, the Delta rack unit’s D/A comverters

will know to get its master clock signal from the ADAT signal at the optical
input of the 

Delta 1010-AI

.

When there is no digital audio signal present at the 

Delta 1010-AI

optical

input, the master clock will be determined by the Delta 1010 Control Panel
setting when the host computer is involved (refer to your Delta 1010 manual),
or in standalone mode by the A/D converters on the Delta 1010 rack-mount
unit.  It is important to be aware of these settings, since incorrect master clock
sync settings can cause undesired anomalies and/or audio artifacts.

If your Delta 1010 PCI card or your Delta 1010 rack unit’s A/D converters are
controlling the sampling clock and you are sending a digital audio signal from
the Delta AI’s optical out, make sure that the device that receives that ADAT 8-
channel signal is set to have its sampling clock determined by the incoming
digital audio signal or the wordclock signal.  On the ADAT, set the input to
“digital,” and the Clock Select to “Digi.”  On digital mixers and other ADAT
Optical capable devices, set the master clock to either “ADAT,” or “wordclock”
if using wordclock for your sampling clock master.  Check your device’s user
guide for advice on setting the master clock synchronization.

10

Summary of Contents for DELTA 1010-AI

Page 1: ...h your Delta 1010 4 Hooking Up Your ADAT Optical Device 5 Using Your Delta 1010 AI 6 ADAT to Host 8 ADAT to Analog Outs 8 Analog Ins to ADAT 9 ADAT Thru 9 Mixed Modes 9 Standalone Mode 9 Master Clock...

Page 2: ...all and configure the Delta 1010 s PCI card Features ADAT I O for PC Windows 95 98 NT Linux and Apple MacOS computers operating up to a full 24 bit 48kHz Provides ADAT record through and playback usin...

Page 3: ...nalog Ins to ADAT Enabled LED When lit this LED indicates that Analog Ins to ADAT mode has been enabled 6 Analog Ins to ADAT Button Pressing this button and locking it to the in position will enable A...

Page 4: ...from the Delta 1010 PCI host card and the Delta 1010 AI Setting up the Delta 1010 AI with your Delta 1010 If you already have your Delta 1010 PCI Recording System installed make sure that you have yo...

Page 5: ...andard for optical cables plugs and jacks Using two good quality TOSLink optical cables 1 Plug one end of an optical cable into the TOSLink optical output jack of your ADAT or other 8 channel ADAT opt...

Page 6: ...10 rack mount unit can also be used in a standalone mode in which the Delta 1010 A D converters send signal directly to the AI s optical output and the Delta 1010 AI optical input connects directly to...

Page 7: ...10 AI in addition to the Delta 1010 analog outs 1 through 8 on the 1010 s rack mount unit by default All other Delta 1010 AI modes are bypassed MIDI I O simply passes through the Delta 1010 AI to the...

Page 8: ...selected from within your music program s audio setup page Once you have opened that page select Wordclock as your master clock source You must also set the Delta control panel to match the sample ra...

Page 9: ...T Optical out of the Delta 1010 AI This default routing is defeated whenever a different source is selected for the ADAT Optical out such as Analog Ins to ADAT Mixed Modes Any combination of Delta 101...

Page 10: ...hen host computer is off or not attached and the Delta 1010 AI is in standalone mode the Delta rack unit s D A comverters will know to get its master clock signal from the ADAT signal at the optical i...

Page 11: ...I O is enabled in the software s MIDI setup page Check your software s documentation You will need to enter a timecode offset into the software s sync setup page also Your BRC may be sending out MTC f...

Page 12: ...roduct requires repair because of user misuse or regular wear it will assess a fair repair or replacement fee The customer will have the option to pay this fee and have the unit repaired and returned...