background image

 

 15 

 

 

 

Assigning a Note to a Trigger Pad 

 
It is possible to configure a pad to send a Note On message when it is struck or held down, and a Note Off message when it is released. 
This requires four values to be specified (values given are examples): 

 

Key 

Parameter 

Value 

Control Assign

Trigger Note On/Off

147

Data 1 (example)

Note Pitch

64 (Note E4)

Data 2 (example)

Note off velocity

0

Data 3 (example)

Note on velocity

100

 

Velocity Lock (Vel Lock) must be active for pads to transmit the note velocities specified by Data 2 and data 3. When Velocity Lock is off, 
the pads will transmit a velocity according to how hard the pad is struck. For further information, please refer to Velocity Lock under 
"Additional Functions". 

 
The following example configures a pad to play MIDI note E4 while it is being held down and stop the note when released.  
 

To configure a pad to play a MIDI note: 

1.

 

Select a pad. See "Control Select (Ctrl Select)". 

2.

 

Press the Edit button. 

3.

 

Press the Control Assign key. The LCD screen will read "ASIGN" and display the currently selected control (for example "P1"), and 
the current MIDI CC assignment (for example "149"). 

4.

 

Enter 147 using the number keys. This sets the pad to trigger MIDI Notes.  

5.

 

Press the Enter key. 

6.

 

Press the Edit button. 

7.

 

Press the Data 1 key (Pitch/Note parameter). The LCD screen will display the currently assigned function ("NOTE"), the selected 
control (for example "P1"), and the current value. 

8.

 

Enter "64" using the number keys. This sets the pad to play MIDI note 64 (E4).  

9.

 

Press the Enter key. 

10.

 

Press the Edit button. 

11.

 

Press the Data 2 key (Velocity Off). The LCD screen will read "MIN" and display the currently selected control (for example as 
"P1"), and the current value (for example "1"). 

12.

 

Enter 0 using the number keys. This sets the pad to transmit a Note Off message with a release velocity value of zero. 

13.

 

Press the Enter key. 

14.

 

Press the Edit button. 

15.

 

Press the Data 3 key (Velocity On). The LCD screen will read "MAX" and display the currently selected control (for example "P1"), 
and the current value (for example "127"). 

16.

 

Enter 100 using the number keys. This sets the pad to transmit a Note On message with a velocity of 100 when struck. 

17.

 

Press the Enter key. 

 
It is also possible to configure a pad or button to send a note on message when it is pressed and a note off message when it is pressed a 
second time. To do this, follow the configuration steps above, but enter 148 for the "Control Assign" parameter. 
 

In most Axiom factory presets, the pads are already programmed to transmit MIDI note data. In order to change the pitch of notes sent, you 
need only follow steps 6 to 9. 

 

Setting Buttons or Sustain Pedals to Send Combined Program 
Change, Bank LSB and Bank MSB messages 

 
The assignable buttons and the Sustain Pedals can be configured to send a multi-part message, consisting of a Program Change, Bank 
LSB and Bank MSB message when pressed. This is useful for specific patch/sound selection from a specific bank of a connected 
synthesizer or virtual instrument. This requires four values to be specified (values given are examples): 
 

Key 

Parameter 

Value 

Control Assign 

Program/Bank Preset select

145

Data 1 (example) 

Program Change Number

42 (GM Instrument Cello)

Data 2 (example) 

Bank LSB number

8

Data 3 (example) 

Bank MSB number

32

 
The following example configures a button or Sustain Pedal to send a total of 3 MIDI messages each time it is pressed (Bank LSB, Bank 
MSB and Program Change), allowing you to recall any sound in any bank of a connected software or hardware synthesizer that supports 
this. 
 

To configure buttons or Sustain Pedals to send combined Program Change, Bank LSB and Bank MSB Messages: 

1.

 

Select a button or Sustain Pedal as described earlier. 

2.

 

Press the Edit button. 

3.

 

Press the Control Assign key. The LCD screen will read "ASIGN" and display the currently selected control (for example "F10"), and 
the current MIDI CC assignment (for example "146"). 

4.

 

Enter 145 using the number keys. This configures the button or Sustain Pedal to send a combined Bank Select/Program Change 
message. 

5.

 

Press the Enter key. 

6.

 

Press the Edit button. 

7.

 

Press the Data 1 key. The LCD screen will display the currently assigned function (for example "NOTE"), the selected control (for 
example "F10"), and the current value. 

8.

 

Enter a Program Change number, such as 42. 

9.

 

Press the Enter key. 

10.

 

Press the Edit button. 

11.

 

Press the Data 2 key. The LCD screen will display the current function assigned to the Data 2 key (in this case, "LSb") and the 
current value. 

12.

 

Enter a Bank LSB number, such as 8. 

13.

 

Press the Enter key. 

Summary of Contents for Axiom AIR 25

Page 1: ...User Guide English...

Page 2: ......

Page 3: ...t on a computer using the included USB cable and set the power switch to the On position The 5 pin MIDI connectors transmits MIDI data to and from Axiom when controlling external hardware synthesizers...

Page 4: ...ndows XP proceed to the next step 6 For Windows XP only do the following After Windows XP identifies the keyboard and asks if you want to search the Internet for a driver select No not this time and c...

Page 5: ...s the pitch The upper and lower pitch bend limit is determined by settings on your hardware or software synthesizer not by the Pitch Bend wheel on Axiom This wheel is spring mounted and returns to the...

Page 6: ...button is illuminated the group is enabled for the operation For example when storing a Patch the group is enabled by default Pressing the button disables and excludes the controls from the newly sto...

Page 7: ...buttons will illuminate and the LCD screen will show the current Program change and active Zone number A direct Program change can then be sent by entering the desired program number using the numeri...

Page 8: ...assigned MIDI CC When pressure is applied to the Strip the LCD screen will display the assigned message type CH AT the active keyboard Zone for example z1 and the value sent for example 0 A unique MI...

Page 9: ...ocation For instructions on how to save a user patch see the Store section Assigning an Axiom control to a Zone MIDI Channel z1 z4 as described in the following section Channel Assign Chan Assign caus...

Page 10: ...sitional value of each control is saved within the patch as the Null values In other words if you use Axiom controls to set up a virtual instrument or synth and save the settings to a patch pressing s...

Page 11: ...ry locations Storing new assignment settings permanently overwrites the contents of the selected memory location To Restore the factory presets hold down the Patch Up and Down buttons during power up...

Page 12: ...ads will generate a fixed velocity value of either 32 64 100 or 127 on a scale of 0 127 depending on how hard or soft they are struck To select a Trigger Pad Velocity Curve 1 Press the Edit button 2 P...

Page 13: ...ntrol for example F10 and the current MIDI CC assignment for example 146 4 Type 10 using the number keys This assigns MIDI CC number 10 Pan to the button 5 Press the Enter key 6 Press the Edit button...

Page 14: ...n to switch between the approximate ten o clock and two o clock positions when pressing and releasing the button Assigning MMC Control to Buttons The transport functions of some hardware recording dev...

Page 15: ...ess the Enter key It is also possible to configure a pad or button to send a note on message when it is pressed and a note off message when it is pressed a second time To do this follow the configurat...

Page 16: ...value 13 Press the Enter key 14 Press the Edit button 15 Press the Data 3 key 16 Enter 127 using the number keys This specifies the maximum value 17 Press the Enter key To configure a button to decre...

Page 17: ...ey The LCD screen will read MAX and display the currently selected control for example F1 and the current value for example 127 8 Enter 0 using the number keys This configures the control to reach its...

Page 18: ...by your device 9 Press the Enter key 10 Press the Edit button 11 Press the Data 2 key The LCD screen will read LSb and display the currently selected control for example E1 and the current value for e...

Page 19: ...Press the highest note to be included in the Zone The LCD screen will display the note value 5 Repeat steps 1 5 to set the range of notes for all remaining Zones Simultaneously holding down multiple...

Page 20: ...iately 5 Repeat steps 1 4 to assign new program numbers for the remaining Zones After configuring the program numbers and exiting Edit mode activate all desired Zones by simultaneously pressing their...

Page 21: ...el pressure Assignable Controls 8 encoders 360 9 faders 40 mm Axiom 49 Axiom 61 1 fader 40 mm Axiom 25 9 fader buttons Axiom 49 Axiom 61 6 transport buttons 8 assignable trigger pads Pitch bend wheel...

Page 22: ......

Page 23: ......

Page 24: ...m audio com Manual Version 1 0...

Reviews: