![Lynx PTG 5610 B/D Reference Manual Download Page 49](http://html1.mh-extra.com/html/lynx/ptg-5610-b-d/ptg-5610-b-d_reference-manual_1953941049.webp)
P TG 5610 B/D Reference Manual. Rev 1.0
Page 49 of 53
New Control Window
Selecting this will open up a new control window with selected the module GUI contained
within. This window can be minimized to the taskbar for fast access and is useful if this
GUI is something you will need to refer to often.
Rename
It is possible to rename everything in the control system selection tree, this includes all
rack names and the individual module names. The descriptions supplied are default
descriptions the system applies. To rename a device simply select the device in the tree,
right click and then select “rename” the dialog below will be displayed
Simply type in the name you wish to assign to this device and press OK. If you wish to
restore the default name simply select “Reset to Factory Default” and press OK
Release
During normal operation if there is no activity on the module GUI for approx ten seconds
then any changed settings are automatically written to flash ram in the module. You can
store the settings immediately by using the release command. When the settings have
been stored you will see the confirmation dialog below.
It is recommended you use the release function before removing any module from the
rack to ensure the latest settings have been stored prior to module removal (if a module
is removed before the normal 10 second timeout then the settings will not be stored)
Lock
Selecting this will lock the device to prevent any accidental changes being made to the
modules settings. The module status can be seen but all the controls will be grayed out.
To unlock simply deselect the lock control from the menu.