Reference Manual P MX 3312/3313 D Version1.3
Page 18
Switch Function Detail
All settings are stored in Flash Ram inside the
module (see Auto Store section in this manual).
Settings will be recalled on power up.
SW 1:
Dip Switch 1
. Full Scale (FS) range select. This switch
is used to select either high or low FS range presets
ON
selects the high range, which means 18dBu (P
MX 3312) or 24dBu (P MX 3313)
OFF
selects the low
range 12dBu or 15dBu (P MX 3312) or 15dBu or
18dBu (P MX 3313) (depending on the selection of
switch 2)
Dip Switch 2
. Select full scale range
(Switch 1 OFF)
ON
=15dBu for P MX 3312 and 18dBu for P MX 3313
OFF
=12dBu for P MX 3312 and 15dBu for P MX 3313
Note
. Switch 1 and switch 2 are interactive
Dip Switch 3
. Mute channel 1. Selecting
ON
will
mute the audio on channel 1
OFF
is normal
operation
Dip Switch 4
. Mute channel 2. Selecting
ON
will
mute the audio on channel 2
OFF
is normal
operation