Step 4: Complete Installation
19
E-EQ-NEMARG-F
NEMA Type 4 Enclosure Reference Guide
Step 4: Complete Installation
After all connections are complete, close the Enclosure door.
There are seven (7) clips around the edges of the Enclosure lid. Ensure that each clip catches the
lip of the Enclosure lid. Tighten the screw for each clip securely.
If desired, install a user-supplied padlock to prevent unauthorized access to the contents of the
Enclosure.
Once the box is secured, return power to the electrical circuit.
Caution
If the Enclosure must be reopened for any reason, the AC power
MUST BE
turned off before opening the enclosure.
Fuse Replacement
Both the 120V and 240V units use a 250V, 5A Fast Blow fuse.
Caution:
For continued protection against risk of fire, replace only with the same type
and rating of fuse
.
The fuse holder is located on the top of the Terminal Block.
To replace the fuse:
1.
Grasp the fuse holder and pull up.
2.
Remove the old fuse and replace with a new fuse of the specified capacity
3.
Close the fuse holder.
Figure 10 Fuse Holder