Installation Procedure, LXE Model 6543 Bridge (non-RoHS)
47
E-EQ-NEMARG-F
NEMA Type 4 Enclosure Reference Guide
159085-0001 Rev. B
Page 5 of 8
9. Position the AC power Transformer in the bracket with the output cord near
the notched tab on the bracket. See figure 6.
10. Remove the adhesive backing and apply the remaining two (2) foam pads to
the transformer, as shown in figure 6
11. Locate the transformer and bracket on the AP Mounting Plate. See figure 7.
12. Secure the bracket with two (2) 6-32 screws.
13. Install a cable tie down on the AP Mounting Plate as shown in figure 7.
14. Plug the power cord in to the Bridge.
Figure 6
Notched Tab
Foam Pads
Figure 7
Cable Tie
Down