LX5000 March 2002
page 45
5
Installation
The LX5000 main unit needs one standrad 80-mm cut-out. Each Vario indicator needs one standrd 57 mm cut-out.
Three pressure connectors are on the rear side of the instrument. A label on the rear side shows their functions.
•
Ptot = Pitot, Total pressure
•
TE = TE probe
•
Pst = Static
Using electronic compensation:
•
TE/Pst Static
•
Pst Static
•
Ptot Pitot
Using TE tube
•
TE/Pst TE tube
•
Pst Static
•
Ptot Pitot
IMPORTANT!
Having changed Ptot and Static, there will be no integrator (average climbing) indication during the flight
The unit is connected to the power via 25 SUB D connector. There is
no fuse in the instrument
so it is
VERY IMPORTANT
to use an external fuse (2A). For power supply extension use min. 0.5 mm² cables.
instrum ent pannel
selector axle
inscripted cover
special type screw
selector
LX5000
Installation of the LX5000
•
Prepare the cutouts in the instrument pannel according to the drilling plans.
•
Remove the inscripted covers from the four main selectors on the LX5000.
•
While holding the selectors, open the screws which are now visible with a screwdriver. Now the selectors may be
removed.
•
Remove the four special type screws.
•
Now position the LX5000 in the cutout in the instrument pannel.
•
Fasten the LX5000 with the special screws.
•
Now the turn knobs and the covers may be fastened again.