KEY LOCK FUNCTION
Use the Key Lock function to prevent any changes to
your settings (in a child’s room, public area… etc)
• To activate the Key Lock function, first press and
maintain the “
OK
” key and then simultaneously on
the left “
” and right “
” navigation keys.
• The key
icon, in section 4 of the LCD display, will be
displayed on the screen.
• Repeat the same procedure to unlock the keypad.
This function is available in all operating modes.
BEHAVIOUR INDICATOR
This is the bar at the bottom of the LCD display that
gives a visual indication of how much energy the
current temperature setting is using i.e.
red
= high
orange = medium
green = low energy comsumption
As you increase the temperature setting, the behavior
indicator “bar” in section 8 of the LCD display, will increase
in length. The opposite applies when decreasing the
temperature setting.
NOTE:
The behaviour indicator is replaced by the program
information bar when in Automatic mode.
4. PARAMETER MENU
The thermostat has a parameter menu. In order to enter
this menu, press and hold the “
OK
” key for 6 seconds.
At 3 seconds, the clock setting screen will appear, but
continue to hold the “
OK
” key for the whole 6 second
period until
, in section 3 of the LCD display, and
“
rFi
” is displayed on the screen.
Parameters can be selected using the left “
” and
right “
” navigation keys. Once the required parameter
is displayed, press the “
OK
” key. Modify the parameter
settings with the “
+
” or “
–
” keys and confirm your
adjustment with the “
OK
” key.
To exit the parameter menu, choose the parameter
“
END
” and press the “
OK
” key.
DEFAULT VALUE & OTHER POSSIBILITIES
00
rFi: WIRELESS RADIO INITIALIZATION (PAIRING)
Press “
OK
” to enter this initialization sequence.
Select with “
+
” or “
–
” the radio communication type
and confirm by pressing the “
OK
” key:
•
rF.un
: unidirectional communication – NOT USED
•
rF.bi
: bidirectional communication with an LVI Touch E3.
The digital thermostat communicates state and power
consumptions to the LVI Touch E3.
Then the backlight will switch off and the digits will cycle
showing that the digital thermostat is waiting for a radio
link signal from an LVI Touch E3 to be received (press “
”
to cancel radio initialization).
When the radio link signal is received, pairing is saved,
then it will return to Auto mode.
NOTE:
Pairing between the devices can be very quick
where cycling of the digits may not be seen.
01
dEG: TYPE OF DEGREES DISPLAYED
Press “
OK
” to enter this parameter. Select with “
+
”
or “
–
” and confirm by pressing the “
OK
” key:
°C = Celsius
°F = Fahrenheit
02
__._ : CALIBRATION OF THE INTERNAL PROBE
The calibration must be done after 1 day working with
the same setting temperature in accordance with the
following description:
Put a thermometer in the room at 1.5m distance
from the floor (like the thermostat) and check the real
temperature in the room after 1 hour.
When you enter the calibration parameter screen the
actual temperature value is displayed.
To enter the value shown on the thermometer, use the
“
–
” or “
+
” keys to enter the real value. At this point the
hand
icon, in section 12 of the LCD display, will be
displayed and the value will blink.
38
GB
GENERAL
INFORMATION