1. GENERAL INFORMATION
• This appliance is a sealed electric radiator designed
for fixed wall-mounted installation.
• This appliance conforms to the standards EN 60335-1
and EN 60335-2-30.
• This appliance is insulation class II and splash resistant
(IP44).
• This appliance complies with European Directive
2004/108/EC (CE Marking on all appliances).
• The product is supplied complete with a connection
cable, wall brackets and screws.
2. INSTALLATION
POSITIONING
• The radiator must be positioned horizontally in
order for it to function correctly.
• The radiator must be positioned according to the
applicable standards. The minimum distances as
specified in picture 1 should be carefully observed.
• The radiator may be positioned inside zone 2 (picture
2) of the bathroom, insofar as no operating controls
(button, switches, etc …) are in reach of persons in the
bath or under the shower.
• The radiator must be fixed to the wall using the
wall brackets supplied.
• The radiator must not be located underneath an
electrical socket.
FIXING
• Mark out the distance between the brackets and the
positions of the screw holes as shown in the table in
picture 3A. Note that 2000 mm long products are supplied
with extra brackets as a 3rd bracket must be fitted in the
middle of the product.
• Note that the brackets can be used to measure the
height of the bottom fixing hole, see picture 3B.
• For the correct installation of radiators it is essential
that the fixing of the radiator is carried out in such a
way that it is suitable for intended use AND predictable
misuse. A number of elements need to be taken into
consideration including the fixing method used to
secure the radiator to the wall, the type and condition
of the wall itself, and any additional potential forces or
weights, prior to finalising installation.
• The fixing materials provided are only intended for
installation on walls made of solid wood, bricks,
concrete or on timber-frame stud walls where the fixing
is directly into the timber. All walls being considered
should have no more than a maximum of 3 mm
wall finishing. For walls made of other materials, for
example hollow bricks; please consult your installer
and/or specialist supplier.
In all cases it is strongly recommended that a suitably
qualified professional installer or similar tradesperson
carries out the installation.
CONNECTION
• The electrical installation must comply with local or
national regulations.
• The radiator should be connected by a suitable and
qualified electrician. Please refer to the wiring diagram
in picture 4 for the connection of the radiator.
• The radiator must be connected to the electrical
supply using the supply cable fitted to the unit using a
switched fused spur having 3mm separation on
all poles.
• If the radiator is installed in a bathroom or shower room,
it must be protected with a residual current device (RCD)
with a rated residual current not exceeding 30 mA.
• The radiator is equipped with a non-resettable overheat
protection that trips off if the radiator overheats. If the
radiator is removed from the wall brackets, even for a
short time, it must without exception be switched off,
see picture 5B. This may even trip the non-resettable
overheat protection. If the overheat protection trips, its
thermal fuse must be replaced; contact your supplier.
3. OPERATION
• The On/Off button is located at the bottom of the control
side of the radiator (C, picture 5). The radiator should
only be switched “on” when it is correctly installed and
secured to the wall brackets (picture 3C). When the
radiator is switched “on”, the LCD screen will illuminate
and all segments will be displayed for a few seconds, then
disappear, before displaying the software version.
31
GB
GENERAL
INFORMATION