- if all mode numbers are issued, the index 2801
h
returns e.g. 0107
h
. (01 = Modules all have a valid
node number, 07 = there are 7 modules)
It is possible to write double node numbers. If the issue of a node number is
triggered but no button is pressed, the command is stopped after 1 minute.
2.4.10.27 Identification - 'Hallo function' (2808
h
)
index
Name
Data type
R/W
Type 1
Type 3
Default
2808
h
Identification - 'Hallo function'
USINT
w
-
During performance of this function, communication via the LOCCbus is
interuppted. The function of the LOCC-Box-Net remains.
This index allows the visualization of a certain module. After the start the respective module flashes for
a fixed time of approx. 10s. This process can only be stopped by pressing the device button.
Activation is achieved by writing an integer value > 0 ´for a corresponding sub-index.
(Sub-Index = node number)
The following error message is generated:
„Attempt to read a write only object“