2.4.10.14 Serial number (2201
h
):
index
name
Data type
R/W
Type 1
Type 3
Default
2201
h
Serial number:
UDINT
r
-
This object delivers the
serial number
of the LOCC-Box. The read value is converted into a decimal
value.
Example:
00 01 E1 EF
h
= decimal = 123375
2.4.10.15 LOCC-Box counter 'Operating voltage ON' (2202
h
)
index
name
Data type
R/W
Type 1
Type 3
Default
2202
h
LOCC-Box counter 'Operating voltage
ON'
UDINT
r
-
This object delivers the
counter reading
stating how often the module has been connected to the
supply voltage. The read value is converted into a decimal value.
Example:
00 00 01 0C
h
= decimal = 268
2.4.10.16 LOCC-Box counter 'Operating hours (h)' (2203
h
)
index
name
Data type
R/W
Type 1
Type 3
Default
2203
h
LOCC-Box counter 'Operating hours (h)'
UDINT
r
-
This object delivers the number of operating hours in ½ hour cycles, i.e. stating how long the LOCC-
Box has been connected to the supply voltage.
The read value is converted into a decimal value and divided by 2.
Example:
00 00 01 60
h
= decimal / 2 = 176h
2.4.10.17 LOCC-Box counter 'Operating hours ON (h)' (2204
h
)
index
name
Data type
R/W
Type 1
Type 3
Default
2204
h
LOCC-Box counter 'Operating hours ON
(h)'
UDINT
r
-
This object delivers the number of operating hours in ½ hour cycles, i.e. stating how long the LOCC-
Box has been connected to the supply voltage.
The read value is converted into a decimal value and divided by 2.
Example:
00 00 08 FB
h