![Lutron Electronics Sivoia QED Technical Reference Manual Download Page 42](http://html.mh-extra.com/html/lutron-electronics/sivoia-qed/sivoia-qed_technical-reference-manual_1950784042.webp)
multiple EDUs
|
individual transformers
|
detail
Sivoia QED
TM
(quiet electronic drive) Shading System
3.15
24/7 Service and Support: 1-800-446-1503
WIRING
Lutron Sivoia QED seeTouch
keypad
BACK
To other
EDUs,
keypads, or
CCIs
To other
EDUs,
keypads, or
CCIs
•
Every keypad, CCI, and EDU is connected by the Sivoia QED
TM
Communication Link.
•
Wire each EDU to a Sivoia QED plug-in transformer, junction-
box-mount transformer, or a Sivoia QED power panel.
•
Each EDU must be EARTH grounded.
•
Each transformer, of any type, can power ONLY ONE EDU,
regardless of shade size.
4
3
2
1
AC
GRD
AC
AC
GRD
AC
female EDU connector
female EDU connector
.75
.7
5
.75
.7
5
Common (Y
ello
w)
+12 VDC
(Blue)
MUX (Gray)
MUX (Purple)
24 V
AC
(Red/White)
24 V
AC
(Red)
EGND (Y
ello
w/Green)
Common (Y
ello
w)
+12 VDC
(Blue)
MUX (Gray)
MUX (Purple)
24 V
AC
(Red/White)
24 V
AC
(Red)
EGND (Y
ello
w/Green)
Wire Legend
Comm Link
(shielded)
Power
SVQ-CBL-250
HW/GRX Link
Line Voltage
See page 3.12 for details
A