![Lutron Electronics Sivoia QED Technical Reference Manual Download Page 14](http://html.mh-extra.com/html/lutron-electronics/sivoia-qed/sivoia-qed_technical-reference-manual_1950784014.webp)
Sivoia QED
TM
(quiet electronic drive) Shading System
1.9
24/7 Service and Support: 1-800-446-1503
ELECTRIC
AL COMPONENTS
electrical
|
individual transformers
Determining which transformer to use depends upon the size of the shade the EDU needs to operate. For up to 50 square feet of
fabric, the 50VA transformer is sufficient. For Sivoia QED treatments up to 225 square feet, either of the 100VA transformers
can be used.
Note:
There is no paralleling of transformer wiring. One transformer may only power one EDU.
All transformers must be earth-grounded.
AC
GRD
AC
SV-50SF-PI
50VA plug-in transformer for up to 50
square feet of fabric.
2.36”
2.88”
1.75”
SV-100SF-PI
100VA plug-in transformer for up to 225 square
feet of fabric.
3.77”
4.95”
3.93”
SV-100SF-JBOX
100VA junction-box mount transformer for up to 225
square feet of fabric.
4.06”
3.48”
4.06”
TRANSFORMER CAPACITY
TYPE
TRANSFORMERS PER
CURRENT PER
TRANSFORMERS PER
20A CIRCUIT
TRANSFORMER
15A CIRCUIT
SV-50SF-PI
.45A
36
44
SV-100SF-PI
.85A
17
23
SV-100SF-JBOX
.85A
17
23
SVQ-10-PNL*
8A/PANEL
1 PANEL
2 PANELS
*Ten EDUs per transformer panel, each EDU must be wired
to a dedicated transformer