![Lutron Electronics Sivoia QED Technical Reference Manual Download Page 13](http://html.mh-extra.com/html/lutron-electronics/sivoia-qed/sivoia-qed_technical-reference-manual_1950784013.webp)
Sivoia QED
TM
(quiet electronic drive) Shading System
1.8
24/7 Service and Support: 1-800-446-1503
ELECTRIC
AL COMPONENTS
electrical
|
transformer panel
SVQ-10-PNL
Simplify the wiring and organize installations that require
multiple transformers. The power panel consists of a 10-output
transformer, 10 fuses and a wire landing board.
Each panel has 10-7 pin connectors for EDUs, each connector is
supplied with power for an individual EDU. The panel contains a
bus that connects the four communication link wires from each
EDU together. It is recommended to home run both EDU and
keypad wiring to the power panel.
Note: Maximum feed breaker size of 30 Amps. Each terminal
block will accept one 10-18 AWG wire. Power panels must be
grounded for safe operation and installed by a licensed
electrician adhering to all local and national codes.
Please see the chart on page 3.12 for specific gauges and
limitations.
Typical components for a Sivoia QED
roller shade system (not shown to scale)
Roller shades
containing
electronic drive
units (up to 64
per link)
Note:
CCI (Contact Closure Input) panels are available to
connect to outside systems such as BMS (Building Management
Systems) or touchscreen systems. See page 1.6
Infrared remote
(optional)
Keypads
(up to 32 per link)
communication
wiring
communication and power wiring
Power/Communications Panel (optional)
•
Sivoia QED shades may also be powered
by individual transformers
.75
.7
5
.75
.7
5
.75
.7
5
Preset
Close
LUTRON
Open
Preset
Close
LUTRON
Open