background image

Page 12

Sivoia

®

 QS 

QSPS-P2-10-60 (CE) 

Installation instructions

Notes:

Summary of Contents for QSPS-P2-10-60

Page 1: ...QS Smart Power Supply Panel CE Installation Instructions QSPS P2 10 60 ...

Page 2: ...ordance with national and local electrical codes 2 QSPS P2 10 60 must be installed by a qualified electrician 3 Ambient operating temperature 0 to 40 C 32 to 104 F 0 to 90 humidity non condensing 4 This product is intended for indoor use only 5 On power up under unfavorable mains conditions this device may cause interfering voltage fluctuations flicker To prevent such interference the system imped...

Page 3: ...A minimum of 300 mm 1 ft is necessary WARNING Risk of death or serious injury Lock the supply breaker in the OFF position before wiring to the terminal blocks 406 mm 16 in 264 mm 10 4 in 121 mm 4 8 in 30 mm 1 2 in 375 mm 14 8 in 445 mm 17 5 in 152 mm 6 in 45 mm 1 8 in 50 x 100 mm 2 x 4 in Bottom Support 2 Connect 230 V power wiring into the QSPS P2 10 60 Remove one of the knockout tabs on the top ...

Page 4: ... 5X20 FUSE 5X20 10 9 8 7 6 5 4 3 2 1 10 9 8 7 6 5 4 3 2 1 1 2 3 4 5 6 7 8 9 10 1 2 3 4 5 6 7 8 9 10 FUSE 5X20 COM MUX MUX COM MUX MUX LINK FUSE 5X20 FUSE 5X20 3 2 1 1 2 3 4 5 6 7 1 2 3 4 5 6 7 8 9 10 FUSE 5X20 FUSE 5X20 FUSE 5X20 10 9 8 7 6 5 4 3 2 1 10 9 8 7 6 5 4 3 2 1 1 2 3 4 5 6 7 8 9 10 1 2 3 4 5 6 7 8 9 10 FUSE 5X20 COM MUX MUX COM MUX MUX LINK 230 V input terminal blocks Spare fuses 5x20 mm...

Page 5: ...lded pair for communications MUX and MUX 3 2 Wire Length Chart Maximum devices per one output Maximum distance per one output based on wire guage Shades Controls 12 AWG 4 mm2 16 AWG 1 5 mm2 18 AWG 1 mm2 GRX CBL 346S 500 None Up to 8 seeTouch QS keypads 1200 ft 350 m 500 ft 150 m 300 ft 75 m 1 Sivoia QS roller 64TM roller 100 roller 200CW or roller 225TM Up to 1 seeTouch QS keypad 500 ft 150 m 200 ...

Page 6: ...4 2 25 sq m 25 sq ft Up to 15 m 50 ft of 1 mm2 18 AWG 4 conductor twisted shielded wire Close Preset Open Meeting Videoconf Afternoon A V Night Off LUTRON Close Open Preset seeTouch QS GRAFIK Eye QS Up to 75 m 250 ft of 1 mm2 18 AWG 4 conductor twisted shielded wire Page Sivoia QS QSPS P2 10 60 CE Installation instructions ...

Page 7: ... Open Meeting Videoconf Afternoon A V Night Off Sivoia QS roller 64 2 25 sq m 25 sq ft Sivoia QS roller 64 2 25 sq m 25 sq ft Up to 30 m 100 ft of 1 mm2 18 AWG 4 conductor twisted shielded wire LUTRON Close Open Preset seeTouch QS Up to 30 m 100 ft of 1 mm2 18 AWG 4 conductor twisted shielded wire Page Sivoia QS QSPS P2 10 60 CE Installation instructions ...

Page 8: ...tron QS shade and lighting devices through the strain reliefs to the terminal blocks Strip insulation wire so that 7 mm 25 in of bare wire is exposed Make sure to tighten the screws tightly and that no insulation is inside of the terminal block Input power from distribution panel Hot Live Neutral Earth Ground Low voltage wiring To Lutron shade and lighting components 1 1 1 Page Sivoia QS QSPS P2 1...

Page 9: ...SPS P2 10 60 panels From additional QSPS P2 10 60 panels To additional QSPS P2 10 60 panels Device Link 4 conductor power and communications to devices Max 600 m 2000 ft per QSPS P2 10 60 Panel Link 3 conductor communications Max 600 m 2000 ft connecting all QSPS P2 10 60 panels 1 1 1 Page Sivoia QS QSPS P2 10 60 CE Installation instructions ...

Page 10: ...8 1 2 3 4 5 6 7 8 9 10 FUSE 5X20 LED FUSE 5X20 FUSE 5X20 10 9 8 7 6 5 4 3 2 1 10 9 8 7 6 5 4 3 2 1 1 2 3 4 5 6 7 8 9 10 1 2 3 4 5 6 7 8 9 10 FUSE 5X20 COM MUX MUX COM MUX MUX LINK If an output status LED has turned off the fuse will need to be replaced The QSPS P2 10 60 comes with two spare 5x20 mm 2 5 A fuses Fuses FUSE 5X20 0 10 9 8 7 6 5 4 3 2 1 9 8 7 6 5 4 3 2 1 4 5 6 7 8 9 10 6 7 8 10 FUSE 5X...

Page 11: ... Communications To verify the communications of your system tap hold 5 seconds tap hold 5 seconds the All Shades Open button The QSPS P2 10 60 is now trying to communicate with all other devices All EDUs communicating on the link will wiggle and flash their green LED quickly If you discover any EDUs that are not wiggling verify that the EDU is powered and wired properly Link Diagnostics Mode will ...

Page 12: ...Page 11 Sivoia QS QSPS P2 10 60 CE Installation instructions Notes ...

Page 13: ...Page 12 Sivoia QS QSPS P2 10 60 CE Installation instructions Notes ...

Page 14: ...Page 13 Sivoia QS QSPS P2 10 60 CE Installation instructions Notes ...

Page 15: ...sions of the National Electrical Code and of the Safety Standards of Underwriter s Laboratories c use of incompatible devices or accessories d improper or insufficient ventilation e unauthorized repairs or adjustments or alterations f vandalism g an act of God such as fire lightning flooding tornado earthquake hurricane or other problems beyond Lutron s control or h direct exposure to corrosive ma...

Page 16: ... Coopersburg PA 18036 United States Tel 1 610 282 3800 Fax 1 610 282 1243 ASIAN HEADQUARTERS Lutron GL Ltd 15 Hoe Chiang Road 07 03 Tower Fifteen Singapore 089316 Tel 65 6220 4666 Fax 65 6220 4333 lutronsea lutron com EUROPEAN HEADQUARTERS Lutron EA Ltd 6 Sovereign Close London E1W 3JF United Kingdom Tel 44 0 20 7702 0657 Fax 44 0 20 7480 6899 CUSTOMER SERVICE ORDERING UK 44 0 20 7702 0657 09 00 1...

Reviews: