51
Bypass
If a sensor is set to bypass, this sensor will not trigger any alarms (does not apply
to tampering alarm), as long as the bypass is active. This option is only available
for sensors that can trigger an alarm.
Please note:
If a sensor displays an error (e.g. low battery), you can ignore this in the menu
“System”
“Status”
“Panel” or via the “Quick access” bar
“Device errors”.
Deactivate tamper
If this function is active, the sensor will not trigger tampering alarms anymore (by
e-mail, text, siren, or wireless relay). However, a warning is still issued if the alarm
panel is armed (or set to Home mode) until the system error is solved or ignored.
Example:
This function can be important if a sensor/tampering contact got loose during
longer periods of absence and you do not want to receive a message concerning
the open tampering contact every time the sensor status is checked.
Report
If this function is active and you use this sensor to change the mode of the alarm
panel (Set/Unset), you receive a notification. Depending on your set-up, this
notification is send via contact ID to an alarm service centre, e-mail, push-
notification, or SMS. If this option is not activated, you do not receive a notification
if you change the mode of the alarm panel with this sensor.
This option does not influence any other alarm or status notifications!
Set/ Unset
Door contacts and sensor inputs feature this function. By means of this function,
you can automatically arm/ disarm the alarm panel. The alarm panel is
automatically armed or disarmed, depending on whether the contact is closed or
open.
o
Normally closed
The sensor is normally closed and arms the alarm panel when opened.
o
Normally open
The sensor is normally open and arms the alarm panel when closed.
Please note
:
o
This function forces the immediate arming/ disarming of the alarm panel,
irrespective of the set delay times or possible system errors (if not set differently in
the menu “Alarm system”
“Settings”
“Area settings”
“Force arm
SET/USNET”)! If you switch this setting to “confirm”, you need to confirm the mode
change again within 10 seconds (e.g. lock the door again).
o
If you want to use several wireless lockswitch contacts and arm the alarm panel
only when the last door is closed, you should assign the additional attribute “Must
be closed before arming” to all wireless sensor inputs. Additionally, you need to
change the setting “Force arm SET/USNET” to “confirm” in the menu “Alarm
system”
“Settings”
“Area settings”.
Must be closed before arming
This function is available for door contacts and sensor inputs. If enabled, it is
impossible to arm the area or set it to home mode, if the door contact with this
option enabled is still open.
Please Note:
o
It is necessary to set “Arming with failure” to “Confirm” in the menu “Alarm
system”
“Settings”
“Area Settings” – otherwise this function does not
work.
o
Home automation rules and scenarios can arm the alarm panel irrespective
Summary of Contents for XT 1 Plus