Resetting the filter runtime
The gesture control will switch automatically to the "Filter runtime" standby display when
the runtime for filter change has been reached for one of the two channels.
The filters of the ventilation component(s) of the corresponding channel should be chan-
ged or cleaned. Please refer to the installation manual for the respective device.
To reset the filter change indicator, hold down the lower operating point for 2-5 s. The
circumferential LED display goes out.
If necessary, repeat the procedure for the other channel and the connected ventilation
components.
Lock control, Learning mode
To lock the control, the operating point in the middle must be held down for 10s. During
pressing, the control pulses every second. If an operation or gesture is made while the
control is locked, the blocking is signalled by a double red light.
If the operating point in the middle of the control is pressed for another five seconds, the
lock is maintained and the control switches to the learning mode. The stored gestures and
operating points can be extensively tested here. A successful gesture or operation is
clearly indicated.
To unlock the control, press and hold the operating point in the middle for 10 seconds. In
that respect, it does not matter in which of the modes described above the control is
currently active.