EQUIPMENT DETAILS
Setting of cooling compartment
temperature
Select the desired cooling compartment
temperature by turning the rotary knob (2).
The scale starts with
MIN
position (small bar =
highest temperature) and climbs up to
MAX
position (large bar = lowest temperature).
Note:
The temperature levels do not relate to
absolute temperature values.
12V:
The refrigerator operates without
thermostatic control (continuous operation).
Mains power (230V)
CAUTION:
This option should only be selected
where the supply voltage of the connection for
power supply corresponds to the value
specified on the data plate. Any difference in
values may result in damage to the appliance.
Gas operation (Liquid gas)
•
The refrigerator must be operated using
liquid gas (propane, butane) (no natural gas
or town gas).
•
When using LPG gas, please consider that
the burner needs cleaning at shorter
intervals due to the gas combustion method
(2-3 times per year recommended).
•
In Europe, gas operation is permitted while
travelling only on the condition that the gas
system of the vehicle is equipped with a
hose rupture protection. The national
regulations of the respective country must
be observed.
•
For physical reasons, gas ignition faults
could occur starting from an altitude above
sea level of approx. 3280 ft. / 1000m (No
malfunction).
•
On the initial refrigerator start-up or after a
cylinder change, air may be trapped in the
gas line. To purge the air from the lines,
switch on the refrigerator and any other gas
appliances (e.g. stove) for a short time. The
gas ignites without delay.
•
Each refrigerator with manual ignition is
equipped with an automatic flame safety
valve which interrupts the gas supply
automaticaly after approx. 30 seconds
when the flame has extinguished.
WARNING: As a basic rule, gas operation is
prohibited in petrol stations!
Prior to starting the refrigerator in gas
mode:
•
Open the gas cylinder valve.
•
Open the shut-off valve for gas supply to
the refrigerator.
Explanation of operating controls
Manual energy selection/automatic ignition
on MES:
1 = Power ON/OFF switch
2 = Energy selector button 230V AC
3 = Energy selector button GAS
4 = Energy selector button 12V DC
6 = Temperature level selection
7 = Temperature level display
8 = Indicator LED failure/Reset button
GAS FAILURE
Switching ON/OFF
Switch ON by pressing button (1), 2s
Switch OFF by pressing button (1), > 2s
230V AC operation
Select "Mains voltage" by pressing button (2)
Set temperature step by pressing button (6)
12V DC operation (vehicle's battery)
Select "Battery voltage" by pressing button (4)
Set temperature step by pressing button (6)
Fig 5
Summary of Contents for Cassini EB 2018
Page 2: ......
Page 4: ...1 2 INTRODUCTION INTRODUCTION...
Page 14: ...6 2 ARRIVAL ON SITE...
Page 56: ...8 38 WIRING DIAGRAMS...
Page 57: ...8 39 WIRING DIAGRAMS...
Page 58: ...8 40 WIRING DIAGRAMS...
Page 59: ...8 41 WIRING DIAGRAMS...
Page 60: ...8 42 CABLE COLOUR CHARTS...
Page 106: ...9 46 EQUIPMENT DETAILS...
Page 114: ...11 4 WARRANTY...
Page 115: ...12 1 NOTES...
Page 116: ...12 2 NOTES...
Page 117: ...12 3 NOTES...
Page 118: ...12 4 NOTES...
Page 124: ...15 2 Designed and Printed by Preset Graphics Tel 01332 549278 Ref 21608...