8-33
3.14
Common Fault Table
(continued)
Fault
Possible Cause
Proposed Fix
Generator being used
‘The Reverse Polarity warning light is on when using my Generator’.
This is a normal side effect when using some types of generator. Instead of connecting the neutral conductor to earth, some generators
centre tap the earth connection making both neutral and live conductors 110V above earth. This 110V difference causes the neon polarity
indicator to illuminate. In most cases it is still safe to use the generator, but please consult the generator handbook for further information.
Control Panel
Control Panel has no
Backlight/illumination may have switched off. Press the select button to reactivate the backlight.
problems
display
Check batteries and fuses, turn PSU shutdown switch and charger switch on and ensure mains supply is connected.
Check control panel connecting lead at PSU and behind Control Panel. Contact your Dealer
12V power turns off
Battery protect feature has operated to protect the Vehicle battery and or the Leisure battery. See 3.5.3.
Engine has been started, all equipment has been disconnected to meet EMC requirements. See 2.7.
Control Panel locked/
Observe control panel handling instructions.
erratic function
Control panel software may have crashed. Reboot control panel by turning off the PSU isolate switch. Wait 30 seconds then turn the
switch back on.
No 12 volt output
No 230V supply
Check all above
from PSU
Charger not switched on
Turn charger switch on, switch will illuminate
Battery not connected
Install charged battery as per 3.5
and/or charged
Power button on control
Turn power on at control panel
panel not switched to on
Battery flat / Battery fuse
Recharge battery, check fuses, check charging voltage is present at battery
blown
Fuse blown
Check all fuses are intact and the correct value fuse is installed as per fuse table
Equipment switched off /
Check equipment is switched on and connected to the 12V supply
unplugged
PSU overheated / auto
Reduce load on system. Allow PSU to cool down. PSU will automatically restart when cool.
shutdown operated
Other fault
Contact your Dealer
Pump not
Fuse blown
Replace fuse with correct value as per fuse table
working
Pump turned off
Turn pump on by pressing the pump button at the control panel
Setting incorrect
Both the internal and external pump feeds are controlledd from the
control panel. To alter the setting of the pump switch see your dealer.
Ensure the setting matches your desired requirement.
SERVICES
Summary of Contents for Cassini EB 2018
Page 2: ......
Page 4: ...1 2 INTRODUCTION INTRODUCTION...
Page 14: ...6 2 ARRIVAL ON SITE...
Page 56: ...8 38 WIRING DIAGRAMS...
Page 57: ...8 39 WIRING DIAGRAMS...
Page 58: ...8 40 WIRING DIAGRAMS...
Page 59: ...8 41 WIRING DIAGRAMS...
Page 60: ...8 42 CABLE COLOUR CHARTS...
Page 106: ...9 46 EQUIPMENT DETAILS...
Page 114: ...11 4 WARRANTY...
Page 115: ...12 1 NOTES...
Page 116: ...12 2 NOTES...
Page 117: ...12 3 NOTES...
Page 118: ...12 4 NOTES...
Page 124: ...15 2 Designed and Printed by Preset Graphics Tel 01332 549278 Ref 21608...