EQUIPMENT DETAILS
•
Most vehicles will reach a comfortable
temperature within 40 mins, in non-extreme
conditions.
Circulation pump is noisy
•
Bleed the system of air.
•
Check the fluid level in the expansion tank.
•
If the inline pump, check speed dial on
pump is set to 2-3.
“Panel failure 1” & "Panel failure 2"
•
Moisture is trapped in the control panel.
•
Remove the Alde control panel from the
vehicle and air in a warm, dry place
overnight.
“Gas failure”
•
Out of gas or gas is not igniting.
•
Check the gas cylinder is full. Try a different
gas cylinder, ensuring it is propane gas.
•
Check the gas regulator and any isolation
valves are open and not frozen.
“Overheat red fail”
or "Overheat blue fail"
•
Bleed the system of air.
•
Check the fluid level in the expansion tank.
It should be 1cm above min mark when
cool.
•
Check the correct circulation pump is
installed, selected and responding.
•
12 V supply to the boiler dropped to 7 V
momentarily. Check 12 V supply for stability.
•
Wait 30 minutes for the fluid to cool down.
“Overheat PCB”
•
Failsafe in boiler has triggered.
•
Check the fluid level in the expansion tank.
It should be 1 cm above the Min mark when
cool.
•
Check the boiler compartment is ventilated
and that the vents are unobstructed. Do not
place stowage in the boiler compartment.
“Fan failure”
•
Combustion fan speed too low after multiple
attempts. Bearing may be stiff after a period
of disuse.
•
Check for instability in 12 V supply.
“Connection failure”
•
Loose connection between Alde control
panel and boiler.
•
Unplug cable at the control panel and boiler,
then carefully plug back in.
•
Check there is slack on the cable at the
control panel, but not excessive weight from
free-hanging/unmanaged cable.
“Window open”
•
Optional window sensor has triggered, gas
heating is suspended. Automatically clears
and gas heating resumes when window is
closed.
“3rd Party Panel C. Fail”
•
Break in comms between Alde control panel
and third party control panel.
•
Check the cable between the Alde control
panel and third party control panel.
•
Third party control panel is installed in
software but not fitted.
•
Untick "Third Party Panel" in Installed
Accessories Menu.
“Low battery”
•
12 V supply to boiler has dropped below
10.5 V, possibly causing system brownout.
•
Automatically clears when 12 V supply
reaches 11 V.
“No match Heater/Panel”
•
EM interference from 230 V power, if cables
are bundled together.
•
Conductive dirt in socket. Plug Alde control
panel cable into the alternative TIN bus
sockets.
If problems persist, please contact Alde, or
your dealer or installer.
For our frequently asked questions, or
download all instruction manuals, please
visit our web site at: www.alde.co.uk
Summary of Contents for Cassini EB 2018
Page 2: ......
Page 4: ...1 2 INTRODUCTION INTRODUCTION...
Page 14: ...6 2 ARRIVAL ON SITE...
Page 56: ...8 38 WIRING DIAGRAMS...
Page 57: ...8 39 WIRING DIAGRAMS...
Page 58: ...8 40 WIRING DIAGRAMS...
Page 59: ...8 41 WIRING DIAGRAMS...
Page 60: ...8 42 CABLE COLOUR CHARTS...
Page 106: ...9 46 EQUIPMENT DETAILS...
Page 114: ...11 4 WARRANTY...
Page 115: ...12 1 NOTES...
Page 116: ...12 2 NOTES...
Page 117: ...12 3 NOTES...
Page 118: ...12 4 NOTES...
Page 124: ...15 2 Designed and Printed by Preset Graphics Tel 01332 549278 Ref 21608...